摘要
分析了GKD3型内燃机车使用的BT-2.6/10AZ型螺杆泵空气压缩机出现过热,最小压力阀烧损的故障原因,提出改善空压机工作环境、加强机车通风散热等处理方法。
The paper analyzes the fault cause of BT-2.6 /10AZ screw pump air compressor's overheating and minimum pressure valve's overburning, and proposes the handling methods such as improvement of air compressor's working environment and enhancement of locomotive ventilation and cooling.
出处
《铁道机车与动车》
2013年第11期46-48,11,共4页
Railway Locomotive and Motor Car
关键词
螺杆泵空压机
最小压力阀
温控阀
screw pump air compressor
minimum pressure valve
temperature control valve