摘要 对邻二氮杂菲分光光度法测定镁合金中铁含量的不确定度来源进行了辨别,并在此基础上对测定过程中的不确定度分量进行了合理评定。测量不确定度主要来源于试样称量、标准溶液配制、校准曲线拟合、各种玻璃量器的使用及测量重复性。依据不确定度评定的步骤,分析和计算得到了各分量标准不确定度及合成标准不确定度,最后合成标准不确定度乘以95%置信概率下的扩展因子2获得测量结果的扩展不确定度。 The source of measurement uncertainty was discussed for the determination of iron in magnesium alloy by orthopenanthroline spectrophotometry.The components of measurement uncertainty were then evaluated correctly. The measurement uncertainty mainly derived from the mass of sample,the preparation of standard solution,the fitting of calibration curve,the application of glass containers and the repeatability of measurements.Based on the evaluation procedure of uncertainty,the standard uncertainty of each component and combined standard uncertainty were analyzed and calculated.Finally, the expanded uncertainty was obtained via multiplying the combined standard uncertainty by 2 which was the expansion factor at 95% confidence level.
作者 任慧 孙建新
出处 《现代科学仪器》 2013年第5期138-141,共4页 Modern Scientific Instruments
关键词 分光光度法 镁合金 不确定度 Spectrophotometry Magnesium alloy Iron Uncertainty
  • 相关文献

参考文献6

二级参考文献8

  • 1国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.62-124.
  • 2刘智敏.不确定度及其应用[M].北京:中国计量出版社,2000..
  • 3HB6731.1-2005铝合金化学成分光谱分析方法第一部分:火焰原子吸收光谱法测定铜含量[S].
  • 4JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 5上海市计量测试技术研究院.常用测量不确定度评定方法及应用实例[M].北京:中国计量出版社,2002.
  • 6中国实验室国家认可委员会.化学分析中不确定度的评估[M].北京:中国计量出版社,2002.
  • 7柯瑞华.化学成分测量不确定度的评定[J].冶金分析,2004,24(1):63-68. 被引量:72
  • 8孙锡丽,葛晓鸣,应海松.火焰原子吸收光谱法测定铁矿石中铜含量不确定度的分析[J].冶金分析,2004,24(1):69-72. 被引量:21

共引文献849

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部