还原分离-原子荧光光谱法分析硅钢中痕量汞的不确定度评定 被引量:1

Evaluation on the Uncertainty of Reduced Separation-Atomic Fluorescence Spectrometry Analyzing Trace Mercury in Silicon Steel and Galvanized Sheet
下载PDF
导出
摘要 用还原分离-原子荧光光谱法分析了硅钢中的痕量汞.分析方法的不确定度主要来自测量重复性,样品溶液浓度,工作曲线变动性,标准溶液,移取、配制标准溶液,仪器变动性等.文章分别对上述构成合成不确定度大小的分量进行了计算讨论. Trace mercury in silicon steel and galvanized sheet was analyzed by adopting reduced separation-atomic fluorescence spectrometry.The uncertainty of the analysis method mainly comes from measurement repeatability,sample concentration,working curve volatility,standard solution,pipetting and preparation of standard solution,and instrument variability,etc.The essay conducted all calculations and discussions on the above components that determine uncertainty.
出处 《首都师范大学学报(自然科学版)》 2013年第5期15-17,共3页 Journal of Capital Normal University:Natural Science Edition
关键词 原子荧光光谱法 硅钢 不确定度 atomic fluorescence spectrometry silicon steel mercury uncertainty.
  • 相关文献