本文根据污水厂地下箱体结构抗浮桩的静力上拔试验 ,分析作为抗拔的静压沉管桩的受力特征及该桩型抗拔力的影响因素 。
According to results static pulling tests of uplift pile structure in a sewerage treatment plant,the puling load transfer mechanism of silent-jacked-tube-and-cast-in-pace pile the effect factors of uplift resistance the method of uplift test and the method of improving uplift resistance are all analyzed in this paper
出处
《福建建筑》
2000年第B11期26-28,共3页
Fujian Architecture & Construction