高压出线装置是超高压变压器的重要部件,其绝缘结构形式直接影响着变压器的整体性能、制造成本、生产周期和装配的工艺性等多个方面。根据电场计算,开发出新式出线装置可以满足各种试验条件和运行条件下的要求,达到保证电气性能、降低制造成本、缩短生产周期和提高装配简便性。
EHV outlet is an important part of EHV transformer, whose insulation structure directly affects the overall performance of transformer and its manufacturing cost, production cycle, assembly process and other aspects. According to the electric field calculation, new type of barrier system can meet the demand of various test and operating conditions, so as to ensure the electric property, reduce manufacturing cost, shorten production cycle and make assembly simple.
出处
《高压电器》
CAS
CSCD
北大核心
2013年第12期150-154,共5页
High Voltage Apparatus
关键词
出线绝缘结构
电场计算
结构对比
工程应用
outlet insulation structure
electric field calculation
structure comparison
project application