摘要 三相并网逆变器采用LCL滤波器,具有更优的高频谐波衰减性,滤波效果更佳,但需考虑谐振抑制问题。针对LCL型并网逆变器的稳定控制展开研究,建立LCL型并网逆变器数学模型,分析了LCL滤波器高频谐振产生的机理和危害,详细介绍了LCL型并网逆变器电流控制、直接功率控制和模拟同步电机控制等方法的原理和应用,展望了LCL型并网逆变器控制的研究热点和研究方向。 The three-phase grid-inverter with LCL filters has superior attenuation for the high frequency and better filter performance. The control stability of the LCL-type grid-connected inverter was studied, the LCL-type photovoltaic inverter mathematical model was established, and the LCL output filter resonance generation mechanism and hazards were analyzed. The control principles and methods of LCL-type photovoltaic inverter on the current dual closed-loop control, direct power control and mimic synchronous generator control was described. At last, the prospects of the LCL-type grid-connected inverter control research focus and research directions were discussed, and the advantages and disadvantages of several control strategies were summarized.
出处 《电源技术》 CAS CSCD 北大核心 2013年第12期2261-2264,共4页 Chinese Journal of Power Sources
基金 中央高校基本科研业务费(201021200066)
关键词 LCL并网逆变器 稳定控制 电流控制 直接功率控制 模拟同步电机控制 LCL grid-connected inverter stability control current control direct power control mimic synchronous generator control
  • 相关文献

参考文献17

  • 1TWMINING E, HOLMES D G. Grid current regulation of a three- phase voltage source inverter with and LCL input filter [J]. IEEE Transactions on Power Electronics, 2003, 18(3): 888-895.
  • 2WANG T C Y, YE Z H, SINHA G, et al. Output filter design for a grid-interconnected three-phase inverter[C]//IEEE Power Electronics Specialists Conference. Acapulco, Mexico: IEEE, 2003: 779-784.
  • 3王要强,吴凤江,孙力,段建东.带LCL输出滤波器的并网逆变器控制策略研究[J].中国电机工程学报,2011,31(12):34-39. 被引量:82
  • 4SHEN G Q, XU D H, CAO L P, et al. An improved control strategy for grid-connected voltage source inverters with an LCL filter [J]. IEEE Trans on Power Electronics, 2008, 23(4): 1899-1906.
  • 5LI Y W. Control and resonance damping of voltage-source and cur- rent-source converters with LCL filters[J]. IEEE Trans on Industrial Electronics, 2009, 56(5): 1511-1521.
  • 6JALILI K, BERNET S. Design of LCL filter of active-front-end two-level voltage-source converters[J]. IEEE Trans on Industry Electron- ics, 2009, 56(5): 1674-1689.
  • 7HU J B, SHANG L, HE Y K, et al. Direct active and reactive power regulation of grid-connected DC/AC converters using sliding mode control approach[J]. IEEE Trans on Power Electronics, 2011, 26(1): 210-222.
  • 8NOGUCHI T, TOMIKI H, KONDO S, et al. Direct power control of PWM converter without power-source voltage sensors [J]. IEEE Trans on Industry Applications, 1998, 34(6): 473-479.
  • 9陈伟,邹旭东,唐健,黄朝霞,李芬,吴振兴,邹云屏.三相电压型PWM整流器直接功率控制调制机制[J].中国电机工程学报,2010,30(3):35-41. 被引量:46
  • 10OYARBIDE E, RAMON J, TORREALDAY. Predictive control strategy for DC/AC converters based on direct power control [J]. IEEE, 2007, 6: 1261-1271.

二级参考文献48

共引文献364

同被引文献44

引证文献6

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部