摘要
针对振动电机使用中频低压电源时工作在大电流状态的现象 ,为了确保电机在足够的起动转矩情况下起动 ,同时不影响振动工作效率 ,探讨分析了中频电源电压设计取值问题 ,指出42 V振动电机可使用 45 V— 2 0 0
Being quoted for a phenomenon of operation of vibration at large current when using the mid frequency low voltage power supply,to ensure that the motor starts at sufficient starting torque while without influencing the working efficiency,this paper discusses and analyzes the problems about selecting the voltage of mid frequency power supply and presents that a 45V,200Hz mid frequency power supply can be applied to 42V vibration motor.
出处
《防爆电机》
2000年第3期16-18,共3页
Explosion-proof Electric Machine
关键词
电压参数
中频电源
振动电机
设计
voltage parameter,mid frequency power supply,vibration motor.