期刊文献+

Effects of Protein on the Detection of Chlorobenzenes in Fish and Their Elimination by Modified QuEChERS Method 被引量:2

Effects of Protein on the Detection of Chlorobenzenes in Fish and Their Elimination by Modified QuEChERS Method
原文传递
导出
摘要 Molecular fluorescence spectrometry, resonance Rayleigh scattering and gas chromatography-mass spectroscopy(GC-MS) were used to study the effect of pure fish serum albumin(FSA) as the model protein on the extraction of three chlorobenzenes(CBs: 1,3-DCB, 1,2-DCB and 1,2,4-TCB; DCB=dichlorobenzene; TCB=trichlorobenzene) in fish samples. The results show that there was a strong binding effect between CB and FSA. In an aqueous solution of 90%(volume fraction) acetone, a slow but full protein denaturation might take place, which would cause the unfolding of protein and the releasing of CBs. Based on these results, a QuEChERS(quick, easy, cheap, effective, rugged and safe) method was modified by replacing the traditional acetonitrile with acetone aqueous solution in the present work. This modified QuEChERS method was applied in the determination of CBs in fish samples. The spiked recoveries and the limits of detection were 80.4%--118.3% and 2.4--7.3 ng/g, respectively. This paper proposes a new strategy by slowing down the protein denaturation and releasing bound organic compounds to enhance the extraction efficiency of CBs in fish samples. Molecular fluorescence spectrometry, resonance Rayleigh scattering and gas chromatography-mass spectroscopy(GC-MS) were used to study the effect of pure fish serum albumin(FSA) as the model protein on the extraction of three chlorobenzenes(CBs: 1,3-DCB, 1,2-DCB and 1,2,4-TCB; DCB=dichlorobenzene; TCB=trichlorobenzene) in fish samples. The results show that there was a strong binding effect between CB and FSA. In an aqueous solution of 90%(volume fraction) acetone, a slow but full protein denaturation might take place, which would cause the unfolding of protein and the releasing of CBs. Based on these results, a QuEChERS(quick, easy, cheap, effective, rugged and safe) method was modified by replacing the traditional acetonitrile with acetone aqueous solution in the present work. This modified QuEChERS method was applied in the determination of CBs in fish samples. The spiked recoveries and the limits of detection were 80.4%--118.3% and 2.4--7.3 ng/g, respectively. This paper proposes a new strategy by slowing down the protein denaturation and releasing bound organic compounds to enhance the extraction efficiency of CBs in fish samples.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2013年第6期1063-1067,共5页 高等学校化学研究(英文版)
基金 Natural Science Foundation of Shandong Province,China
关键词 CHLOROBENZENE Modified QuEChERS(quick easy cheap effective rugged and safe) method Gas chromatography-mass spectroscopy Fluorescence spectrometry Resonance Rayleigh scattering Chlorobenzene Modified QuEChERS(quick,easy,cheap,effective,rugged and safe) method Gas chromatography-mass spectroscopy Fluorescence spectrometry Resonance Rayleigh scattering
  • 相关文献

参考文献30

  • 1Kozani R.R.,Assadi Y.,Shemirani E.,Hosseini M.R.M.,Jamali M.R.,Talanta,2007,72,387.
  • 2Jia F.Y.,Wang W.W.,Wang J.,Yin J.G.,Liu Y.M.,Liu Z.B.,Anal.Methods,2012,4,449.
  • 3Li G.Z.,Liu Y.M.,Guo X.Y.,Wang J.J.,Acta Chimica Sinica,2006,64,679.
  • 4Wang X.R.,Liu Z.B.,Jia E.Y.,Zhang Q.,Yin J.G.,Liu Y.M.,Acta Chimica Sinica,2011,69,2505.
  • 5Wang X.R.,Zhu X.J.,Liu Y.M.,Chem.Res.Appl.,2010,22,763.
  • 6Wang Y.,Lee H.K.,J.Chromatogr.A,1998,803,219.
  • 7Barro R.,Ares S.,Garcia-Jares C.,Llompart M.,Cela R.,J.Chromatogr A,2004,1045,189.
  • 8Santos E,Sarrion M.,Galceran M.,J.Chromatogr.A,1997,771,181.
  • 9Wennrich L.,Popp P.,Breuste J.,Chromatographia Supplement,2001,53,380.
  • 10Wells D.E.,De Boer J.,Tuinstra L.G.M.T.,Reutergardh L.,Griepink B.,Fresenius Z Anal.Chem.,1988,332,591.

同被引文献5

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部