摘要
介绍了制氧机组循环水系统采用无压回水的缺点和采用有压回水的优点,提出了循环水系统由无压回水改为有压回水的可行性和应注意的问题。
The disadvantages of using backwater without pressure and advantages of us- ing backwater with pressure in the circulating water system of oxygen generating unit are in- troduced, while the feasibility of replacing the backwater system without pressure with pressur- ized water system and attention points in the change are put forward.
出处
《冶金动力》
2013年第12期22-23,26,共3页
Metallurgical Power
关键词
制氧机组
供排水系统
无压回水
有压回水
oxygen generating unit
water supply and draining system
backwater with-out pressure
backwater with pressure