摘要
针对130 t/h煤气锅炉低压省煤器系统设计与运行特点,分析其震动原因,提出了运行中的有效的降低排烟温度、提高机组效率、节约能源的调整控制手段。
Causes of vibration trouble of the low-temperature coal economizer for the 130 t/h gas boiler were analyzed in accordance with the design and operation characteristics of the coal economizer. Some effective modification and control measures to reduce flue gas temperature, improve system efficiency and save energy were also put forward.
出处
《冶金动力》
2013年第12期30-31,34,共3页
Metallurgical Power
关键词
低压省煤器
回热系统
烟气温度
锅炉负荷
震动
low-temperature coal economizer
recuperation system
flue gas temperature
boiler load
vibration