摘要 目的 :探讨可曲导光纤维喉镜电视监控下检查钳取下咽部尖锐异物的方法。方法 :局部 1 %的卡因表面麻醉 ,以可曲导光纤维喉镜经鼻道或口腔入路 ,电视监控下检查钳取异物65例。结果 :间接喉镜下检查、取出较困难的 65例下咽部尖锐异物中 ,会厌谷异物 2 5例(38 5% )、舌根深部异物 2 1例 (32 3% )、梨状窝异物 1 9例 (2 9 2 % ) ,均经可曲导光纤维喉镜电视监控下顺利取出 ,且无一例发生明显创伤等并发症。结论 :可曲导光纤维喉镜电视下钳取下咽部异物 ,可克服间接喉镜下检查及钳取下咽异物的缺点和局限 ,患者易于配合、痛苦小 ,具有检查全面、观察清晰、定位准确、钳取灵活的优点 ,可显著提高手术成功率 ,减少创伤及并发症。 Objective:To investigate the method of taking out sharp foreign bodies in lower pharynx(SFBLP) by flexible optic fiber laryngoscope with monitoring TV(FOFLTV).Methods:SFBLP were examined and taken out by FOFLTV via nose or mouth by local surface anaesthesia with 1% dicaine solution.Results:Among sixty five cases,age ranged from 16 to 69 years old.Foreign bodies were found at vallecula,deep part of tonge root and piriform fossa in 25(38 5%),21(32 3%) and 19(29 2%),respectively.The SFBLP can be apparently examined and taken out safely by FOFLTV.Conclusion:To examine and take out the SFBLP by FOFLTV can overcome the shortcomings of taking SFBLP by indirect laryngoscope.This method has the advantages of thorough examining,accurate focusing and safely removing SFBLP with little trauma or complications.And patients feel comfortable and cooperate well with doctors.
出处 《中日友好医院学报》 2000年第5期279-282,共4页 Journal of China-Japan Friendship Hospital
关键词 异物 纤维光学 喉镜检查 pharynx foreign bodies fiber optics laryngoscopy
  • 相关文献

参考文献2

  • 1陆兴,陈望燕.喉咽部异物76例报告[J].临床耳鼻咽喉科杂志,1995,9(4):237-238. 被引量:7
  • 2张小华.纤维喉镜下钳取下咽异物[J].中国耳鼻咽喉颅底外科杂志,1998,4(3):179-179.

共引文献7

同被引文献13

引证文献9

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部