为TS30全站仪配置不同的反射目标:GPR1标准棱镜、GPH1P精密棱镜、Leica 1.5〞RRR反射球、Leica 40mm×40mm反射片、柯达灰板[1]。在室内30m的范围内将全站仪与激光干涉仪比测,测试TS30全站仪在近距离上对不同反射目标的测距精度,希望能给相关人员提供一些参考。
Configuring different reflective targets for TS30 total station: leica GPR1 standard prism ,leica GPH1P precise prism,leica 1.5 * Red--Ring reflector, leica 40 mm× 40mm reflective tape, kodak Gray Card. Comparing the range ac- curacy of total station with laser interferometer within 30m indoor to test the range accuracy in a close distance of TS30 to- tal station for different reflectors, hope to provide some reference to the people in related area.