期刊文献+

光电容积脉搏波临床应用研究进展 被引量:12

下载PDF
导出
摘要 光电容积描记术(Photoplethysmography,PPG)是一种运用光电技术在活体组织中监测血容积变化的无创监测方法。近年来PPG监测技术以及数字信号处理功能进一步发展,且操作简便,性能稳定,具有安全可靠、实时、无创伤以及适应性强等诸多优点,受到国内外学者广泛关注。它包含人体丰富的生理病理信息,从最初的对SpO2及脉率的监测,发展到从PPG中提取形态学参数对呼吸系统、循环系统以及应激反应的监测。本文就PPG的测量原理及形态特征、影响因素、最新技术进展及未来展望作简要综述。
出处 《临床麻醉学杂志》 CAS CSCD 北大核心 2013年第11期1132-1134,共3页 Journal of Clinical Anesthesiology
基金 南京医科大学科技发展重点基金项目资助(07NMUZ041) 南京市卫生人才培养工程基金
  • 相关文献

参考文献18

  • 1Sahni R. Noninvasive monitoring by photoplethysmography. Clin Perinatol, 2012, 39(3): 573-583.
  • 2Korhonen I, Yli-Hankala A. Photoplethysmography and no- ciception. Aeta Anaesthesiol Scand, 2009, 53(8) :975-985.
  • 3Yan YS, Zhang YT. An efficient motion-resistant method for wearable pulse oximeter. IEEE Trans Inf Teehnol Biomed, 2008, 12(3) :399-405.
  • 4徐建国,孙杰,杨建军,沈锦春,贾真.不同脉搏血氧饱和度监测仪临床应用性能的比较[J].中华麻醉学杂志,2007,27(11):1054-1055. 被引量:6
  • 5Awad AA, Haddadin AS, Tantawy H, et al. The relation- ship between the photoplethysmographic waveform and sys- temic vascular resistance. J Clin Monit Comput, 2007, 21 (6) : 365-372.
  • 6Huiku M, Uutela K, van Gils M,et al. Assessment of surgi- cal stress during general anaesthesia. British Journal of An- aesthesia, 2007, 98(4):447-455.
  • 7Gruenewald M, Meybohm P, Ilies C, et al. Influence of dif- ferent remifentanil concentrations on performance of the sur- gical stress index to detect a standardized painful stimulus during sevoflurance anaesthesia. Br J Anaesth, 2009, 103 (4) :586-593.
  • 8Chen X, Thee C, Gruenewald M,et al. Comparison of surgi- cal stress index-guided analgesia with standard clinical prac- tice during routine general anesthesia: a pilot study. Anes- thesiology,2010, 112 (5): 1175-1183.
  • 9徐磊,仲艳玲,朱中良,朱娟,鲍红光.指脉搏图波幅变化与全凭静脉麻醉药物作用的相关性[J].临床麻醉学杂志,2011,27(11):1056-1058. 被引量:6
  • 10De Felice C, Goldstein MR, Parrini S, et al. Early dynamic changes in pulse oximetry signals in preterm newborns with histologic chorioamnionitis. Pediatr Crit Care Med, 2006, 7 (2) : 138-142.

二级参考文献12

  • 1杨军良,陈伯銮.新的静脉麻醉药:双异丙酚[J].国际麻醉学与复苏杂志,1992,26(3):129-132. 被引量:59
  • 2罗宝蓉,康孝荣,王保国.末梢灌注指数监测全麻患者应激反应的评价[J].中华麻醉学杂志,2007,27(2):117-119. 被引量:14
  • 3Ehrenfeld JM, Funk LM, Van Schalkwyk J, et al. The incidence of hypoxemia during surgery: evidence from two institutions. Can J Anaesth, 2010, 57: 888-897.
  • 4Solus-Biguenet H, Fleyfel M, Tavernier B, et al. Non-inva sive prediction of fluid responsiveness during major hepatic surgery. BrJ Anaesth,2006, 97: 808-816.
  • 5Westphal GA, Silva E, Goncalves AR, et al. Pulse oximetry wave variation as a noninvasive tool to assess volume status in cardiac surgery. Clinics, 2009,64: 337-343.
  • 6Tsuchiya M, Yamada T, Asada A. Pleth variability index predicts hypotension during anesthesia induction. Acta Anaesthesiol Scand 2010,54: 596-602.
  • 7Thomson IR, Harding G, Hudson RJ. A comparison of fent anyl and sufentanil in patients undergoing coronary artery by pass graft surgery. J Cardiothorac Vasc Anesth, 2000, 14 :652-656.
  • 8Ahonen J, Olkkola KT, Hynynen M, et al. Comparison of alfentanil, fentanyl and sufentanil for total intravenous anaes- thesia with propofol in patients undergoing coronary artery bypass surgery. Br J Anaesth, 2000,85: 533-540.
  • 9Eichhorn JH. Prevention of intraoperative anesthesia accidents and related severe injury through safety monitoring. Anesthesiology, 1989, 70: 572- 577.
  • 10Aoyagi T, Miyasaka K. Pulse oximetry: its invention, contribution to medicine, and future tasks. Anesth Analg, 2002, 94(1 Suppl):S1-S3.