摘要 目的评价Angio-Seal、StarClose血管闭合器与人工压迫止血在冠脉介入治疗中安全性及有效性。方法回顾性分析了2008年1月—2012年12月在本院接受冠状动脉介入治疗的945例患者,按不同止血方法随机分为人工压迫组(205例)、A ngio-Seal组(324例)和StarClose组(416例),观察各组制动时间、止血成功率及血管并发症的发生情况。结果与人工压迫组相比,Angio-Seal组和StarClose组制动时间明显缩短(P<0.01),血管并发症的发生率降低(P<0.01);三组的止血成功率比较差异无显著性意义(P>0.05)。结论在冠脉介入治疗中应用Angio-Seal和StarClose血管闭合器是安全、可靠的。 Objective To evaluate the safety and efficacy ofAngio-Seal, StarClose vascular closure device and manual compression in the coronary intervention.Methods Retrospective analysis of 945 patients underwent coronary intervention therapy from January 2008 to December 2012 in our hospital, according to different methods to stop bleeding, they were randomly divided into manual compression gr0up(205 cases), Angio-Seal gr0up(324 cases)and StarClose group(416 cases), to observe the braking time, hemostatic success rate and vascular complications.Results Compared with manual compression, the braking time of Angio-Seal group and StarClose group was significantly shorter(P〈0.01), the incidence of vascular complications is decreased (/9〈0.01); There are no significant differences in the hemostatic success rate of the three groups(P〉0.05).Conclusion It is safe and reliable to The apply the Angio-Seal and StarClose vascular closure device in coronary intervention therapy.
作者 金刚 张顺祥
出处 《中国卫生产业》 2013年第30期19-20,共2页 China Health Industry
关键词 冠脉介入 ANGIO-SEAL血管封堵器 StarClose血管闭合器 并发症 Angio-Seal occluder StarClose vascular closure device Complication
  • 相关文献

参考文献8

  • 1Prada-Delgado (O),Estévez-Loureiro R,Calvi(n)o-Santos R,et al.Safety and efficacy of femoral vascular closure devices in patients undergoing primary percutaneous coronary intervention for ST-elevation myocardial infarction[J].Am Heart J,2011,161(6):1207-1213.
  • 2Interact Cardio Vasc Thorac Surg,2011,12:400-403.
  • 3Das R,Ahmed K,Athanasiouo T,et al.Arterial closure devices versus manual compression for femoral haemostasis in interventional radiologieal Procedures:a systematic review and meta-analysis[J].Cardiovase Interveut Radiol,2011,34(4):723-738.
  • 4乔志强,张敏州,李松,程康林,赵新军.应用股动脉血管封堵器后严重血管迷走反射一例[J].中国介入心脏病学杂志,2006,14(1):60-60. 被引量:9
  • 5Smith TP,Cruz CP,Moursi MM.et al.Infectious complications resulting from use of hemostatic puncture closure devices[J].Am J Surg,2001,182(6):658-662.
  • 6Osbom LA,Sunderman H,Langsfeld M.Common femoral artery stenosis after deployment of vascular clip closurc device[J].Catheter Cardiovasc lnterv,2008,71:736-737.
  • 7Koreny M,Riedmuller E,Nikfarajam M,et al.Arterial puncture closing devices compared with standard manual compression after cardiac catheterization systematic review and meta-analysis[J].JAMA,2004,291(3):350-357.
  • 8Smilowitz NR,Kirtane AJ,Guiry M,et al.Practices and complications of vascular closure devices and manual compression in patients undergoing elective transfemoral coronary procedures[J].Am J Cardiol,2012,110(2):177-82.