期刊文献+

大清生物纸在人工髋关节置换术中的应用 被引量:2

下载PDF
导出
摘要 目的 评估大清生物纸在人工髋关节置换术(THA)后止血的有效性及安全性.方法 2012年10月至2013年3月39例行THA患者采用传统止血加大清生物纸进行止血,将2012年3月至9月行THA手术的41例患者作为对照组,采用传统止血.比较两组患者术后24 h引流量、输血量、术前与术后l天血红蛋白(Hb)下降值区别.结果 试验组术后输血量、24 h引流量、Hb下降值均较对照组明显减少.结论 大清生物纸在THA术中具有较好的止血效果后良好安全性.
出处 《国际医药卫生导报》 2013年第24期3779-3781,共3页 International Medicine and Health Guidance News
  • 相关文献

参考文献6

  • 1Gocen Z, Sen A, Unver B, et al.The efect of preoperative Physiotherapy and education on the outcome of total hip replacement:a prospective randomized controlled trial[J]. Clin-Rehabil, 2004, 18 ( 4 ) : 353- 358.
  • 2Millner RW, Lockhart AS, Bird H, et al. A new hemostatie agent: initial life-saving experience with Celox (chitosan) in cardiothoracic surgery[J].Ann Thorac Surg, 2009, 87(2): e13-14.
  • 3田晓滨,张美心,张祖根,韩伟,李波.改良Gibson入路行全髋关节置换术[J].贵州医药,1999,23(4):268-269. 被引量:9
  • 4Havelin LI, EngesaeterLB, Espehaug B, et al.Then orw egian arthroplasty register:l 1 years and 73 000 arthrop lasties[J].Acta Orthop Scand, 2000, 71 ( 4 ) : 337- 353.
  • 5巴根,赵贵成,傅强.可吸收止血材料的安全性与临床应用[J].第二军医大学学报,2011,32(8):911-914. 被引量:29
  • 6Kumar MN, Muzzarelli RA, Muzzarelli C, et al.Chitosan chemistry and pharmaceutical perspectives[J].Chem Rev, 2004, 104(12): 6017-6084.

二级参考文献26

  • 1Jamborova G, Pospisilova N, Semecky V, Hyspler R, Ticha A, Pospechova K, et al. Microdispersecl oxidized cellulose as a novel potential substance with hypolipidemic properties[J]. Nutrition,2008,24:1174-1181.
  • 2Krizova P, Masova L, Suttnar J, Salaj P, Dyr J E, Homola J, et al. The influence of intrinsic coagulation pathway on blood platelets activation by oxidized cellulose[J]. Biomed Mater Res A, 2007,82 : 274-280.
  • 3Chapman W C, Singla N, Genyk Y, McNeil J W, Renkens K L Jr,Reynolds T C, et al. A phase 3, randomized, doubleblind comparative study of the efficacyand safety of topical recombinant human thrombin andbovine thrombin in surgical hemostasis[J]. Am Coll Surg, 2007,205 : 256 -265.
  • 4Crean S,Michels S,Moschella K,Reynolds M. Bovine thrombin safety reporting:an example of study design and publication bias[J]. Surg Res,2010,158:77-86.
  • 5Tredree R B W, Debrix I, Eisert A. Evaluating the difference between fibrin sealants:recommendations from an international advisory panel of hospital pharmacists[J].EJHP Sci, 2006,12:3-9.
  • 6Fergusson D A, Hebert P C, Mazer C D, Fremes S, MacAdams C,Murkin J M,et al. A comparison of aprotinin and lysine ana- logues in high risk cardiac surgery[J]. N Engl J Med, 2008, 358:2319-2331.
  • 7Gahay M. Absorbable hemostatie agents[J]. Am J Health Syst Pharm, 2006,63 : 1244-1253.
  • 8Vargas M A. Dentin bonding: effects of hemostatic agents and caries detectors[J].Esthet Restor Dent, 2009,21 : 75-76.
  • 9Kim I Y,Eichel L,Edwards R,Uribe C,Chou D S,Abdelshehid C, et al. Effects of commonly used hemostatic agents on the porcine collecting system[J]. J Endourol, 2007,21 : 652-654.