摘要 The purpose of this study was to investigate the influence of different luting agents on the stress distribution within the crown, abutment and peri-implant bone of implant-supported all-ceramic single crown. A three-dimensional finite element model of an implant-supported single crown for the first premolar of mandible was created by COSMOS 2.85. Resin-modified glass ionomer and two different resin adhesives were used to cement the crown and abutment. Vertical 600 N and horizontal 225 N loads were applied to stimulate the condition of chewing. The stress distributions within the all-ceramic crown, abutment and peri-implant bone were analyzed. The experimental results show that the stress distributions of all-ceramic crown, abutment, implant and peri-implant bone were similar when different luting agents were used. The result of present study indicated that luting agents had no influence on the stress distributions of implant-supported all-ceramic single crown. The purpose of this study was to investigate the influence of different luting agents on the stress distribution within the crown, abutment and peri-implant bone of implant-supported all-ceramic single crown. A three-dimensional finite element model of an implant-supported single crown for the first premolar of mandible was created by COSMOS 2.85. Resin-modified glass ionomer and two different resin adhesives were used to cement the crown and abutment. Vertical 600 N and horizontal 225 N loads were applied to stimulate the condition of chewing. The stress distributions within the all-ceramic crown, abutment and peri-implant bone were analyzed. The experimental results show that the stress distributions of all-ceramic crown, abutment, implant and peri-implant bone were similar when different luting agents were used. The result of present study indicated that luting agents had no influence on the stress distributions of implant-supported all-ceramic single crown.
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1227-1230,共4页 武汉理工大学学报(材料科学英文版)
基金 Funded by the National Natural Science Foundation of China(No.81100784)
关键词 stress distributions dental implants luting agent ALL-CERAMIC stress distributions dental implants luting agent all-ceramic
  • 相关文献

参考文献1

二级参考文献1

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部