详述了安装在JEM-2100高分辨透射电镜上的Olympus CCD图像采集系统的使用技巧和参数设置,包括电子束强度的调整、图像亮度以及对比度的调整、图片标尺的显示和标定、电子衍射分析图片采集、特殊情况下样品观察和图片采集、电子束过曝保护设置、荧光屏抬起和落下控制、CCD与TEM的通讯恢复等。
Usage skills and parameters setting of Olympus CCD installed in JEM-2100 TEM were narrated, which included adjusting the intensity of electron beam, adjusting the contrast and brightness of images; scale displaying and calibrating; properly acquiring image in SAED; observing samples and acquiring images in special cases; protective setting of over-exposure; controlling the putting up and down of the fluorescent screen; restoring the communication between CCD and TEM, etc.
出处
《理化检验(物理分册)》
CAS
2013年第12期813-818,共6页
Physical Testing and Chemical Analysis(Part A:Physical Testing)
基金
青岛科技大学博士启动基金资助项目(0022503)