为完全分解样品,消除碳的影响,以H2S04+HN03冒烟消除碳,甲酸还原,王水溶解,在ICP-AES选定的条件下测定废钯炭催化剂样品中钯的含量。样品加标回收率97.0%-101.6%测定0.099%-0.324%的钯含量,相对标准偏差2.55%~2.84%,方法与灼烧还原法及火试金法测定结果一致,方法简单快速,环保节约,结果准确。
In order to decomposes the sample completely and eliminate the impact of carbon, preparation of sample, carbon removed by H2SOa+HNO3 smoking, formic acid reduction, dissolved by aqua regia. determine palladium content in the selected conditions of ICP-AES. The recovery ranged from 97.0% to 101.8%, the relative standard deviation (n=6) is less than 3%, determination result of the method and method of ignition reduction and fire assay is consistent, the method is simple and fast, environmental protection, conservation, and accurate.