介绍莱城发电厂基建配置的传统型电除尘器的本体结构、供电方式及运行效率现状,分析制约其效率提高的主要因素;对新型转动极板电除尘器技术进行较为详细的分析,阐述莱城发电厂应用该技术对电除尘器进行改造的技术方案及改造后效果。
This article firstly introduced the structure,power supply and performance of the traditional electrostatic precipitator in Laicheng Power Plant,analyzed the performance affecting aspects including dust characteristic,the fume character,the parameter and performance for the real configuration,the controlled quality for the power supply;then analyzed the principle and configuration of rotary electrode plate electrostatic precipitator,introduced the technological reformation,and presented result about electrostatic precipitator technological reformation has been implemented.