期刊文献+

下颌无牙颌种植体支持SynCone套筒冠固位覆盖义齿的临床观察 被引量:2

Clinical evaluation of mandibular implant-support overdenture by ankylos SynCone conical crowns
下载PDF
导出
摘要 目的:探讨应用Ankylos种植系统SynCone基台行下颌无牙颌种植体支持覆盖义齿修复的临床效果。方法:17例下颌无牙颌患者,在下颌植入4枚Ankylos种植体,2~3个月后行种植体水平转移并采用SynCone基台制作种植覆盖义齿,戴牙后3、6、12、18个月复查,进行临床和放射学检查。结果:17例患者中无种植体脱落现象,种植体周软组织健康,x线检查未见明显骨吸收,义齿固位力好、稳定,患者对修复效果满意。结论:在下颌植入4枚种植体,使用SynCone基台行种植体支持覆盖义齿修复效果明显,操作简单,易于维护,患者满意度高,值得推广。 Objective: To clinically evaluate patients with a mandibular implant-supporteu overuemme zy ankylos SynCone conical crowns. Methods: Seventeen patients were treated with implant-support over- denture by ankylos SynCone conical crowns, and each was implanted four Ankylos implants in mandible. Results: All implants survived. All implants had no obvious frontal resorption in 12-18 months of follow-up. All of the patients were satisfied with the implant-support overdent^res. Conclu- sion: Ankylos syncone abutment applied to mandibular implant-support overdenture is an effective method.
作者 谭冠柳
出处 《中国口腔种植学杂志》 2013年第4期188-190,198,共4页 Chinese Journal of Oral Implantology
关键词 牙种植 覆盖义齿 套筒冠 dental implant, overdenture, conical crown
  • 相关文献

参考文献10

  • 1Geertman ME, Slagter AP, van Waas MA, Kalk W. Comminution of food with mandibular implant-re- tained overdentures. J Dent Res. 1994, 73 (12) : 1858 -64.
  • 2Sadowsky SJ. Mandibular implant-retained overden- tures: a literature review.J Prosthet Dent. 2001, 86 (5) : 468-73.
  • 3刘朴,王小容,张艳,杨小东.按扣型附着体下颌种植覆盖义齿咀嚼效率比较[J].中国口腔种植学杂志,2009,14(3):51-55. 被引量:5
  • 4徐世同,祯峥,周磊,朱晓斌,徐淑兰,宋光保,张雪洋.下颌无牙颌杆卡种植覆盖义齿修复的临床疗效观察[J].广东牙病防治,2004,12(3):230-232. 被引量:7
  • 5May D, ROMANOS G E. Immediate implant-sup-ported mandibular overdentures retained by conical crowns: A new treatment concept [J] . Quintessence international, 2002, 33 (1) : 5-12.
  • 6K~rber K. Konuskronen, Das rationelle Teleskop- system Einfuhrung in Klinik und Technik [J] . Dr Alfred Htithig Verlag GmbH, Heidelberg, 1988: 78- 84.
  • 7张仁国,Wolfgang B.Hannk,Markus Roggensack,Wolfgang B.Freesmeyer.SynCone套筒冠式即刻负重种植系统的固位特性研究[J].中国口腔种植学杂志,2009,14(4):101-104. 被引量:3
  • 8Naert I, Gizani S, Vuylsteke M, et al. A 5 - year prospective randomized clinical trial on the influ- ence of splinted and unsplinted oral implants retain- ing a mandibular overdenture: prosthetic aspects and patient satisfaction [J] . Journal of oral rehabil- itation, 1999, 26 (3) : 195-202.
  • 9朱安棣,郭泽鸿,容明灯,周东风,周磊.种植体支持套筒冠覆盖义齿联合栓道附着体咬合重建的临床效果[J].广东牙病防治,2009,17(9):443-445. 被引量:4
  • 10Krennmair G, Weinlander M, Krainhofner M, et al. Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: a 3-year prospective study [J] . The International journal of prosthodontics, 2006, 19 (2) : 164.

二级参考文献40

  • 1Albrektsson T, Zarb G, Worthington P, et al. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants, 1986,1 ( 1 ) : 11-25.
  • 2Albrektsson T, Zarb G A. Current interpretations of the osseointegrated response: clinical significance. Int J Prothodont, 1993,6 (2) : 95-105.
  • 3Romanos GE. Present status of immediate loading of oral implants. J Oral Implantol, 2004,30 ( 3 ) : 189-197.
  • 4Buser D, Weber HP, Bragger U, et al. Tissue integration of one- stage IT1 implants : 3-year results of a longitudinal study with Hollow- Cylinder and Hollow-Screw implants. Int J Oral maxillafac Implants, 1991,6(4) :405-412.
  • 5Hellem S, Karlsson U, Almfeldt I, et al. Nonsubmerged implants in the treatment of the edentulous lower jaw : a 5-year prospective longitudinal study of IT1 hollow screws. Clin Implant Dent Relate Res, 2001,3( 1 ) :20-29.
  • 6Chiapasco M, Abati S, Romeo E. et al. Implant-retained with o Branemark mandibular overdentures System MKII implants: a prospective comparative study between de layed and immediate loading. Int. J. Oral Maxillofac. Implants., 2001; 16:537-546.
  • 7Romeo E, Chiapasco M, Lazza A. et al. Implant-retained mandibular overdentures with ITI implants. Clin. Oral. Implants. Res., 2002; 13: 495-501.
  • 8Gatti C and Chiapasco M. Immediate loading o of Branemark implants: a 24-month follow-up of a comparative prospective pilot study between mandibular overdentures supported by conical transmucosal and stan-dard MKII implants. Clin. Implant. Dent. Relat. Res., 2002; 4: 190-199.
  • 9Lorenzoni M, Perti C, Zhang K. Et al. In-patient comparison of immediately loaded and non-loaded implants within 6 months. Clin. Oral. Implants. Res., 2003; 14: 273-279.
  • 10Chiapasco M and Oatti C. Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants. Clin. Implant. Dent. Relat. Res., 2003; 5: 29-38.

共引文献15

同被引文献6

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部