摘要 感应式磁场传感器广泛应用于地球物理电磁勘探仪器,但也是阻碍我国地球物理电磁勘探仪器装备研发和推广应用的瓶颈技术.在我国SinoProbe计划中"地面电磁探测(SEP)系统"项目支持下,我们研制出用于大地电磁测深(the Magnetotellurics MT)方法的高灵敏度磁场传感器.研制过程中,采用磁通负反馈技术,增强传感器系统工作稳定性;采用斩波稳零放大电路技术,有效降低低频1/f噪声对传感器灵敏度的影响;采用高磁导率合金材料,增加磁场传感器的灵敏度.最终,MT磁场传感器工作频率范围为1 mHz^1kHz,噪声水平0.1Hz时为1.5pT/Hz;1Hz时为0.15pT/Hz;10Hz时为0.03pT/Hz;长度96cm,重量≤6kg.理论和测试结果表明:与同类产品比较,本文研制的感应式磁场传感器在≥10Hz时,平均噪声水平从150fT/Hz,下降至30fT/Hz,噪声水平更优,测量精度更高,能够更好地满足MT方法的需求. The search coil magnetometer (SCM) is a kind of magnetic sensors which is applied widely in oil and mineral explorations,earthquake monitoring,space research and so on.Also SCM is one of indispensable roles in EM exploration device.Funded by China's SinoProbe Plan,the SCM with high sensitivity for the Magnetotellurics (MT) is developed.In this article,the SCM with magnetic flux negative feedback structure is described.The chopper stabilized circuit is applied for removal of the 1/f noise in low frequency.The mu-metal core with high permeability increases the sensitivity of the SCM.The theoretical and test results show that the bandwidth of the SCM is from 1 mHz to 1 kHz,the noise level at 0.1 Hz is 1.5 pT/(√)Hz,at 1 Hz is 0.15 pT/(√)Hz,and at 10 Hz is 0.03 pT/(√)Hz,respectively.The length of the SCM is 96 cm,diameter is 60 mm,and the weight is less than 6 kg.The SCM presented here can meet the demand of the magnetotellurics (MT) method.
出处 《地球物理学报》 SCIE EI CAS CSCD 北大核心 2013年第11期3683-3689,共7页 Chinese Journal of Geophysics
基金 国家科技专项"深部探测技术与实验研究专项(SinoProbe-09-02)" 自然科学基金项目(41374186)联合资助
关键词 感应式磁场传感器 大地电磁测深 斩波稳零放大电路 1 f噪声 高磁导率磁芯 Search coil magnetometer Magnetotellurics Chopper stabilized circuit 1/f noise Mu-metal core
  • 相关文献

参考文献9

二级参考文献102

共引文献318

同被引文献313

引证文献32

二级引证文献263

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部