期刊文献+

过碳酸盐洗衣机槽清洗剂相关性能及评价方法的研究 被引量:4

INVESTIGATION ON THE PERCARBONATE CLEANING AGENTS FOR WASHING TANK AND THE EVALUATION METHOD
下载PDF
导出
摘要 目的研究过碳酸盐洗衣机槽清洗剂相关性能和评价方法。方法采用悬液定量杀菌试验、金属腐蚀性试验和现场试验的方法进行实验研究。结果以含6.25g/L过碳酸盐洗衣机槽清洗剂的水溶液,作用120min,对大肠杆菌、金黄色葡萄球菌、白色念珠菌的平均杀灭率分别为100%、99.98%、99.91%,有机物浓度升高,杀菌效果明显减弱。注水至洗衣机最高水位,加入洗衣机槽清洗剂250g,作用120min,使洗衣机水中微生物的平均杀灭率为98.45%,第二次注水后测得洗衣机槽微生物的清除率为83.27%,第三次注水后测得洗衣机槽微生物的清除率为92.01%。过碳酸盐洗衣机清洗剂对不锈钢基本无腐蚀,对铜和铝为轻度腐蚀,对碳钢为中度腐蚀。结论过碳酸盐洗衣机槽清洗剂对污染的洗衣机有良好的杀菌和清洁作用,对金属有一定的腐蚀性,有机物对杀菌效果有一定的影响。 Objective The aim of the study is to know the effect of the percarbonate cleaning agent for washing tank and the evaluation method. Methods Suspension quantitative germicidal test, metal corrosion test method, and field test were used. Results The average killing rate was 100%, 99.98%, 99.91% for Escherichia eoli, Staphylococcus aureus, and Candida albicans by using percarbonate aqueous cleaning agent ( 6.25g/L ) to wash tank for 120 min, respectively. However, when organic concentration increased, the bactericidal effect was significantly weakened. When water in washing machine was in the highest level, 250g detergent was added into washing tank for 120 rain, the average killing rate to bacteria in the water was 98.45%, 83.27% after the second adding water, and 92.01% after the third adding water. Percarbonate cleaning agents almost had no corrosion on stainless steel, but mild corrosion on copper and moderate corrosion on carbon steel.Conclusion The percarbonate cleaning agents has a good bactericidal and cleansing effect on the contamination of the washing machine, and had some corrosion on the metal.
出处 《中国卫生标准管理》 2013年第4期24-28,共5页 China Health Standard Management
关键词 过碳酸盐 洗衣机槽清洗剂 有机物 杀菌效果 微生物 清洗效果 腐蚀性 评价方法 Percarbonate Cleaning agent for washing tank Organics Bactericidal and cleansing effect Bacteria Corrosion Evaluation method
  • 相关文献

参考文献3

二级参考文献10

  • 1Cafiso V. Bertuccio T, Santagati M, et al. Presence of the ica operen in clinical isolates of Staphylococcus epidermidis and its role in biofilm production [ J ]. Clinical Microbiol Infect, 2004, 10 (12) :1081.
  • 2Brown M R W, Gibert P. Sensitivity of biofilm to antimicrobial agents [ J ]. Journal of Applied Microbiology, 1993,74 ( 1 ) : 87.
  • 3Karen V, Aniko P. Removal of biofilm from endoscopes: Evaluation of detergent efficiency [ J ]. AJIC,32 (3) : 170.
  • 4Alfa M J, DeGagne P, Olson N, et al. Comparision of ion plasma, vaporized hydrogen peroxide, and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer[ J ]. Infect Cont Hosp Epidemiol, 1996,17 ( 1 ) :92.
  • 5Faser VJ, Zuckerman G, Clouse RE, et al. A prospective randomized trial comparing manual and automated endoscope disinfection methods[J]. Infect Cont Hosp Epidemiol,2003,14(4) :383.
  • 6Vyas A, Picketing CAC, Oldham LA, et al. Survey of symptoms, respiratory function, and immunology and their relation to glutaraldehyde and other occupational exposures among endoscopy nursing employee[ J]. Occup Envirn Med ,2000, 57 (7) :752.
  • 7Nguyen -Khoa M, Degremont A, Jean -Claude D, et al. Evidence of bacterial biofilm in tubing from hydraulic pathway of hemodialysis system [ J ]. Artificial Organs, 1998,22 (7) :596.
  • 8Gilbert P, McBain AJ. Biofilms: their impact on health and their recalcitrance toward biocides[ J ]. American journal infect control, 2001,29(2) :252.
  • 9Pajkos A, Vickery K, Cossart Y. Is bioflim accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination? [ J ]. Journal of Hospital Infection,2004,58 (2) :224.
  • 10胡征宇,陆用海.洗涤剂配方原理(三)[J].日用化学工业,1992,22(3):40-47. 被引量:3

共引文献38

同被引文献17

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部