掌侧解剖型锁定钢板治疗不稳定型桡骨远端骨折疗效分析 被引量:6

CURATIVE EFFECT OF VOLAR ANATOMICAL LOCKING PLATE IN FIXATION OF UNSTABLE DIS-TAL RADIUS FRACTURES
原文传递
导出
摘要 目的探讨掌侧解剖型锁定钢板治疗不稳定型桡骨远端骨折的疗效。方法2010年1月-2012年7月,应用掌侧解剖型锁定钢板系统治疗32例不稳定型桡骨远端骨折患者。术后进行随访,观察手术治疗效果。结果32例患者均得到随访,随访时间为8~18个月(平均12.5个月),腕关节功能根据Garland与Werley评分标准,优10例,良18例,可3例,差1例。优良率87.5%。结论使用掌侧解剖型锁定钢板治疗不稳定型桡骨远端骨折疗效满意,个体化的康复指导仍十分重要。 Objective To observe the clinical outcome of the volar anatomical locking plate in fixation of unstable distal radius fractures. Methods From January 2010 to July 2012, 32 cases with unstable distal radius fractures were treated by volar anatomical locking plate. Follow- up after operation was performed to observing the effect of operation treatment. Results All patients were followed up for an average of 12.5 months(range from 8- 18 months). According to Garland and Werley to assess wrist joints function, excellent was in 10 cases, good was in 18 cases, ordinary was in 3 ease, bad in 1 case, and with an excellent to good rate of 87.5%. Conclusion Volar anatomical locking plate fixation is effective for the treatment of unstable distal radius fractures, and rehabilitation guidance of individual is also very important.
出处 《中国煤炭工业医学杂志》 2013年第12期1941-1943,共3页 Chinese Journal of Coal Industry Medicine
关键词 桡骨远端骨折 锁定钢板 手术治疗 Distal radius fractures Locking plate Operation
  • 相关文献

参考文献8

二级参考文献48

  • 1王其友,蔡道章,徐义春,董健文,卢华定.锁定加压接骨板在桡骨远端粉碎性骨折治疗中的应用[J].中华手外科杂志,2004,20(3):162-163. 被引量:22
  • 2冯翔宇,冯经旺,尹憬颀,沈景辉,谭志伟,冯运华,汤克沪.掌侧支撑钛钢板固定治疗桡骨远端粉碎性骨折[J].中华创伤骨科杂志,2006,8(3):272-273. 被引量:27
  • 3Hanel DP, Jones MD, Trnmble TE. Wrist fractures. Orthop Clin North Am, 2002, 33: 35-57.
  • 4Henry MH. Distal radius fractures: current concepts. J Hand Surg (Am), 2008, 33: 1215-1227.
  • 5Rikli DA, Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg (Br), 1996, 78: 588-592.
  • 6Jupiter JB, Marent-Huber M, LCP Study Group. Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg (Am), 2009, 91: 55-65.
  • 7Sarmiento A, Pratt GW, Berry NC, et al. Colles' fractures. Functional bracing in supination. J Bone Joint Surg(Am), 1975, 57: 311-317.
  • 8Hove LM, Nilsen PT, Furnes O, et al. Open reduction and internal fixation of displaced intraarticular fractures of the distal radius. Thirty-one patients followed for 3-7 years. Acta Orthop Scand, 1997, 68: 59-63.
  • 9Kamano M, Honda Y, Kazuki K. Palmar plating for dorsally displaced fractures of the distal radius. Clin Orthop Relat Res, 2002, (397): 403-408.
  • 10Blythe M, Stoffel K, Jarrctt P. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: a biomechanical study in cadavers. J Hand Surg (Am), 2006, 31: 1587-1593.

共引文献144

同被引文献30

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部