摘要 采用阴离子色谱交换柱进行分离,非抑制型电导离子色谱法检测,直接进样测定矿泉水中的偏硅酸含量。结果硅酸盐浓度在5~100mg/L范围内线性关系良好,相关系数为0.9998,回收率在99.57%~101.50%之间。即采用非抑制型离子色谱法检测矿泉水中偏硅酸的方法简单快速,结果准确可靠,对环境无污染,适合矿泉水中偏硅酸的检测。 Samples were directly injected and followed by separating analytes by ion chromatography and detecting metasilicic acid in mineral water by a non-suppressed conductivity detector. Results: The linearity of silicate was favorable in the range of 5N100mg/L and the correlation coefficient was 0.9998. The recovery ranged from 99.5717% to 101.4950%. Being simple, rapid and pollution-free to the environment, the method, with accurate and reliable results, is suitable for the determination of metasilicic acid (H2SiO3) in mineral water.
出处 《饮料工业》 2013年第12期31-32,38,共3页 Beverage Industry
关键词 矿泉水 偏硅酸 离子色谱 非抑制型电导检测 mineral water metasilicic acid ion chromatography non-suppressed conductivity detection
  • 相关文献

参考文献4

二级参考文献12

  • 1许秀娥.用修正法准确计算加标回收率[J].河北化工,1995,18(2):55-57. 被引量:2
  • 2任成忠,毛丽芬.加标回收实验的实施及回收率计算的研究[J].工业安全与环保,2006,32(2):9-11. 被引量:86
  • 3中国环境监测总站环境水质监测质量保证手册编写组.环境水质监测质量保证手册[M].2版.北京:化学工业出版社,1994:228-229,300.
  • 4GB/T5750.3-2006,生活饮用水标准检验方法;水质分析质量控制[S].
  • 5DZ/T0130.6-2006,地质矿产实验室测试质量管理规范;第6部分:水样分析[S].
  • 6国家环境保总局水和废水监测分析方法编委会.水和废水监测分析方法[M].4版.北京:中国环境科学出版社,2002:31.
  • 7加标回收率[ZB/OL].http:∥baike.baidu.com/view/1918830.htm?fr=ala0-1[2009-09-10].
  • 8GB/T8538-2008,硅钼黄分光光度法[S].
  • 9姚运先.水环境监测[M].北京:化工出版社,2005.
  • 10王桂琴,张景发.水分析质量控制的应用[J].岩矿测试,2008,27(3):239-240. 被引量:1

共引文献52

同被引文献52

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部