期刊文献+

Fast analysis of thiocyanate by ion-pair chromatography with direct conductivity detection on a monolithic column 被引量:2

Fast analysis of thiocyanate by ion-pair chromatography with direct conductivity detection on a monolithic column
原文传递
导出
摘要 Fast analysis of thiocyanate by ion-pair chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e using tetrabutylammonium hydroxide (TBA)-phthalic acid-acetonitrile as eluent. The effects of eluent concentration, eluent pH value, column temperature and flow rate on retention time of thiocyanate were investigated. The optimized chromatographic conditions for the determination of thiocyanate were as follows: 0.25 mmol/L TBA-0.18 mmol/L phthalate-7% acetonitrile (pH 5.5) as eluent, column temperature of 30 ℃, and flow rate of 6.0 mL/min. Retention time of thiocyanate was less than 1 min under the conditions. Common anions (Cl^-, NO3 , SO42 and I^- ) did not interfere with the determination of thiocyanate. Detection limit (S/N = 3) of thiocyanate was 0.96 mg/L. Calibration graph between peak area and the concentration of thiocyanate was linear in the range of 2.0- 100.0 mg/L. Relative standard deviation (RSD) of chromatographic peak area was 1.4% (n = 5). This method has been applied to the determination of thiocyanate in ionic liquids. Recoveries of thiocyanate after spiking were 100.5%. Fast analysis of thiocyanate by ion-pair chromatography using a silica-based monolithic column and direct conductivity detection was carried out. Chromatographic separation was performed on a Chromolith Speed ROD RP-18e using tetrabutylammonium hydroxide (TBA)-phthalic acid-acetonitrile as eluent. The effects of eluent concentration, eluent pH value, column temperature and flow rate on retention time of thiocyanate were investigated. The optimized chromatographic conditions for the determination of thiocyanate were as follows: 0.25 mmol/L TBA-0.18 mmol/L phthalate-7% acetonitrile (pH 5.5) as eluent, column temperature of 30 ℃, and flow rate of 6.0 mL/min. Retention time of thiocyanate was less than 1 min under the conditions. Common anions (Cl^-, NO3 , SO42 and I^- ) did not interfere with the determination of thiocyanate. Detection limit (S/N = 3) of thiocyanate was 0.96 mg/L. Calibration graph between peak area and the concentration of thiocyanate was linear in the range of 2.0- 100.0 mg/L. Relative standard deviation (RSD) of chromatographic peak area was 1.4% (n = 5). This method has been applied to the determination of thiocyanate in ionic liquids. Recoveries of thiocyanate after spiking were 100.5%.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第12期1067-1069,共3页 中国化学快报(英文版)
基金 supported by the Program for Scientifc and Technological Innovation Team Construction in Universities of Heilongjiang Province (No. 2011TD010)
关键词 Monolithic Ion-pair chromatography Thiocyanate Conductivity detection Monolithic Ion-pair chromatography Thiocyanate Conductivity detection
  • 相关文献

参考文献3

二级参考文献37

  • 1J. Yin, G. Yang, Y. Chen, et al. J, Chromatogr. A 1090 (2005) 68.
  • 2J. Ou, L. Kong, C. Pan, et al. J. Chromatogr. A 1117 (2006) 163.
  • 3H. Li, Y. Liu, Z, Zhang, et al. J. Chromatogr. A 1098 (2005) 66.
  • 4H. Kim, G. Guiochon, Anal. Chem. 77 (2005) 93.
  • 5J. Liu, Q. Deng, K. Yang, et al. J. Sep, Sci. 33 (2010) 2757.
  • 6H. Liu, X. Zhuang, M. Turson, et al. J. Sep. Sci. 31 (2008) 1649.
  • 7H.W. Sun, F.X. Qiao, G.Y. Liu, J. Chromatogr. A 1134 (2006) 194.
  • 8X. Liu, C. Ouyang, R. Zhao, et al, Anal. Chim. Acta 571 (2006) 23.
  • 9H. Yan, K.H. Row, Biomed. Chromatogr. 22 (2008) 48.
  • 10X. Sun, J. He, G. Cai, et al. J. Sep. Sci. 33 (2010) 3786.

共引文献16

同被引文献19

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部