期刊文献+

Glucose biosensor based on new carbon nanotube–gold–titania nano-composites modifed glassy carbon electrode 被引量:2

Glucose biosensor based on new carbon nanotube–gold–titania nano-composites modifed glassy carbon electrode
原文传递
导出
摘要 In this paper, a novel biosensor was prepared by immobilizing glucose oxidase (GOx) on carbon nanotube-gold-titania nanocomposites (CNT/Au/TiO2) modified glassy carbon electrode (GCE). SEM was initially used to investigate the surface morphology of CNT/Au/TiO2 nanocomposites modified GCE, indicating the formation of the nano-porous structure which could readily facilitate the attachment of GOx on the electrode surface. Cyclic voltammogram (CV) and electrochemical impedance spectrum (EIS) were further utilized to explore relevant electrochemical activity on CNT]Au/TiO2 nanocomposites modified GCE. The observations demonstrated that the immobilized GOx could efficiently execute its bioelectrocatalytic activity for the oxidation of glucose. The biosensor exhibited a wider linearity range from 0.1 mmol L-1 to 8 mmol L^-1 glucose with a detection limit of 0.077 mmol L^- 1. In this paper, a novel biosensor was prepared by immobilizing glucose oxidase (GOx) on carbon nanotube-gold-titania nanocomposites (CNT/Au/TiO2) modified glassy carbon electrode (GCE). SEM was initially used to investigate the surface morphology of CNT/Au/TiO2 nanocomposites modified GCE, indicating the formation of the nano-porous structure which could readily facilitate the attachment of GOx on the electrode surface. Cyclic voltammogram (CV) and electrochemical impedance spectrum (EIS) were further utilized to explore relevant electrochemical activity on CNT]Au/TiO2 nanocomposites modified GCE. The observations demonstrated that the immobilized GOx could efficiently execute its bioelectrocatalytic activity for the oxidation of glucose. The biosensor exhibited a wider linearity range from 0.1 mmol L-1 to 8 mmol L^-1 glucose with a detection limit of 0.077 mmol L^- 1.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2013年第12期1087-1090,共4页 中国化学快报(英文版)
基金 support from National Key Basic Research Program (No. 2010CB732404) National Natural Science Foundation of China (No. 21175020) Qinglan Project Sci-Tech Innovation Team of Jiangsu Province Suzhou Science & Technology Major Project (No. ZXY2012028)
关键词 Biosensor Glucose oxidase CNT/Au/TiO2 Biosensor Glucose oxidase CNT/Au/TiO2
  • 相关文献

参考文献18

  • 1Zhi Jun Luo,Ting Ting Han,Ling Ling Qu,Xiang Yang Wu.A ultrasensitive nonenzymatic glucose sensor based on Cu_2O polyhedrons modified Cu electrode[J].Chinese Chemical Letters,2012,23(8):953-956. 被引量:2
  • 2Aili Sun,Jianbin Zheng,Qinglin Sheng.A highly sensitive non-enzymatic glucose sensor based on nickel and multi-walled carbon nanotubes nanohybrid films fabricated by one-step co-electrodeposition in ionic liquids[J].Electrochimica Acta.2012
  • 3Hongfang Zhang,Zuchao Meng,Qi Wang,Jianbin Zheng.A novel glucose biosensor based on direct electrochemistry of glucose oxidase incorporated in biomediated gold nanoparticles–carbon nanotubes composite film[J].Sensors & Actuators: B Chemical.2011(1)
  • 4Christopher B. Jacobs,M. Jennifer Peairs,B. Jill Venton.Review: Carbon nanotube based electrochemical sensors for biomolecules[J].Analytica Chimica Acta.2010(2)
  • 5QinShen,Sun‐KyungYou,Soo‐GilPark,HuiJiang,DadongGuo,BaoanChen,XuemeiWang.Electrochemical Biosensing for Cancer Cells Based on TiO<sub>2</sub>/CNT Nanocomposites Modified Electrodes[J].Electroanalysis.2008(23)
  • 6Yan‐LiYao,Kwok‐KeungShiu.Direct Electrochemistry of Glucose Oxidase at Carbon Nanotube‐gold Colloid Modified Electrode with Poly(diallyldimethylammonium chloride) Coating[J].Electroanalysis.2008(14)
  • 7Ruifang Gao,Jianbin Zheng.Amine-terminated ionic liquid functionalized carbon nanotube-gold nanoparticles for investigating the direct electron transfer of glucose oxidase[J].Electrochemistry Communications.2008(3)
  • 8Caifeng Nan,Yan Zhang,Guomei Zhang,Chuan Dong,Shaomin Shuang,Martin M.F. Choi.Activation of nylon net and its application to a biosensor for determination of glucose in human serum[J].Enzyme and Microbial Technology.2008(5)
  • 9Xinyu Pang,Dongmei He,Shenglian Luo,Qingyun Cai.An amperometric glucose biosensor fabricated with Pt nanoparticle-decorated carbon nanotubes/TiO 2 nanotube arrays composite[J].Sensors & Actuators: B Chemical.2008(1)
  • 10Xin Huang Kang,Zhi Bin Mai,Xiao Yong Zou,Pei Xiang Cai,Jin Yuan Mo.A novel sensitive non-enzymatic glucose sensor[J].Chinese Chemical Letters,2007,18(2):189-191. 被引量:1

二级参考文献27

  • 1J, Hu, Biosens. Bioelectron. 24 (2009) 1083.
  • 2S. Park, H. Boo, T.D. Chung, Anal. Chim. Acta 556 (2006) 46.
  • 3C. Su, C. Zhang, G.Q. Lu, et al. Electroanalysis 22 (2010) 1901.
  • 4Y.Z. Xian, Y. Hu, E Liu, et al. Biosens. Bioelectron. 21 (2006) 1996.
  • 5L.M. Lu, L. Zhang, EL. Qu, et al. Biosens. Bioelectron. 25 (2009) 218.
  • 6X.H. Kant. Z.B. Mai. X.Y. Zou. et al. Chin. Chem. Lett. 18 (2007) 189.
  • 7R. Qiu, X.L. Zhang, R. Qiao, et al. Chem. Mater. 19 (2007) 4174.
  • 8F. Xiao, F.Q. Zhao, D.P. Mei, et al. Biosens. Bioelectron. 24 (2009) 3481.
  • 9J.P. Wang, D.E Thomas, A,C. Chen, Anal. Chem. 80 (2008) 997.
  • 10F.Q. Zhao, F.B. Xiao, Z. Zeng, Electrochem. Commun. 12 (2010) 168.

共引文献1

同被引文献4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部