期刊文献+

AP1000核电厂厂外剂量风险定量化分析 被引量:1

Offsite Dose Risk Quantification Analysis for AP1000 Nuclear Power Plant
下载PDF
导出
摘要 为了分析APl000核电厂各种潜在的严重事故对周围公众的影响,采用MACCS程序模拟释人大气中气载放射性物质的弥散过程,对6种代表性释放类别进行剂量风险定量化分析。计算结果表明,事故后24h内厂址边界附近公众的急性红骨髓剂量风险为1,96×10^7Sv/(堆·年),该风险大部分来自安全壳旁通释放(BP);早期健康效应风险在10^10~10“Sv/(堆·年),且随着与反应堆距离的增大降幅明显;集体全身有效剂量风险为6.94×10^-4人·Sv/(堆·年),引发的癌症致死风险非常低。研究结果还表明,核事故后及时撤离将显著降低公众剂量风险。 In order to estimate the potential offsite effect caused by severe accidents of AP1000 nuclear power plant, radiation dose risk was quantified, which takes into ac-count six representative release categories. Atmospheric transport with airborne radio active material was simulated by MACCS code. The results show that acute red marrow dose risk at the site boundary is 1.96 X 10 7 Sv/(reaetor year), which mainly results from containment bypass release (BP). The early health effect risks are 10-1-10 9 Sv/ (reactor year), and the risks decrease obviously with the increase of distance from reac- tor. Population whole-body effective dose risk is 6.94 X 10 4 person Sv/(reactor year), and the corresponding cancer fatality risk is quite low. The study result also indi cates that timely evacuation after the nuclear accident can reduce public dose risk significantly.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2013年第12期2288-2292,共5页 Atomic Energy Science and Technology
关键词 严重事故 剂量风险 早期健康效应 severe accident dose risk early health effect
  • 相关文献

参考文献6

  • 1JOW J L,SPRUNG J L,ROLLSTIN L T,etal. MELCOR accident consequence code system(MACCS), model description[M], USA: SandiaNational Laboratories, 1990; 2-10.
  • 2VALENTIN J. The 2007 recommendations ofthe international commission on radiological pro-tection[M]. Canada: The International Commis-sion on Radiological Protection, 2007 : 53.
  • 3胡二邦,高占荣.应用分段烟羽模式估算秦山核电厂(二期)设计基准事故概率后果[J].环境科学学报,1998,18(2):181-187. 被引量:3
  • 4樊申,谢建伦,张应超.秦山核电厂全厂断电事故厂外后果分析[J].原子能科学技术,2006,40(6):698-702. 被引量:6
  • 5TENERA L P. Advanced light water reactorutility requirements document [R]. Palo Alto:Electric Power Research Institute, 1999.
  • 6国家核安全局,国家环境保护总局.核事故辐射应急时对公众防护的干预原则和水平,HAF0703[R].北京:国家核安全局,1990.

二级参考文献8

  • 1樊申,张应超,季松涛.秦山Ⅰ期核电厂全厂断电事故源项研究[J].原子能科学技术,2006,40(5):553-558. 被引量:8
  • 2胡二邦,J Environ Sci,1994年,6卷,292页
  • 3胡二邦,核事故场外辐射后果评价方法,1988年
  • 4CHANIN D I,SPRUNG J L,RITCHIE L T,etal.MELCOR accident consequence code system(MACCS)[M].Vol 1.USA:Sandia National Laboratories,1990:1-35.
  • 5JOW J L,SPRUMG J A,ROLLSTIN L T,et al.MELCOR accident consequence code system(MACCS)[M].Vol 2.USA:Sandia National Laboratories,1990:1-13.
  • 6SUMMERS R M,STEPHEN W W,PAUL D,et al.MELCOR computer code manual[M].Vol1.USA:Sandia National Laboratories,1991:1-19.
  • 7何国祥,顾汉,杜风雷,等.秦山核电厂环境影响报告书(试运行阶段)[R].浙江:秦山核电公司,2001.
  • 8国家核安全局,国家环境保护总局.核事故辐射应急时对公众防护的干预原则和水平,HAF0703[R].北京:国家核安全局,1990.

共引文献7