摘要 本文对不同隔热层材料组成的消防服的热防护性能进行了实验测试与分析验证,评价了新型组合式消防服和传统组合式消防服的隔热性能优劣。结果表明以SiO2气凝胶材料为隔热层的新型组合式消防服的导热系数约为传统型的1/4,具有更显著的热防护效果。 This paper evaluates the thermal protective performance of active firefighter suit and new combined clothing with SiO2 aerogel as thermal barrier through experimental test and numerical analysis. The results show that the clothing, in which SiO2 aerogel composite was used, have more effective heat insulation as its thermal conductivity is only 1/4 times as much as the traditional suit.
出处 《中国个体防护装备》 2013年第6期20-24,共5页 China Personal Protective Equipment
关键词 消防服 气凝胶 热防护 导热系数 fire protective clothing aerogel thermal protective thermal conductivity
  • 相关文献

参考文献5

二级参考文献11

  • 1GB8965.1-2009.防护服装阻燃防护第1部分:阻燃服中国标准出版社.2009.
  • 2GA10-2002.消防员灭火防护服.中国标准出版社.2009.
  • 3http://www.cippe.net/down/1/24718.htm.
  • 4Luis A. Trevino, et al. Aerogel-Based Insulation for Advanced Space Suit. SAE 2002, 2002-01-2316.
  • 5Henry H., et al. Thermal Performance of Space Suit Elements with Aerogel Insulation for Moon and Mars Exploration. SAE 2006, 2006-01-2235.
  • 6GA10-2002.消防员灭火防护服[S].[S].,..
  • 7北京大学数学力学系概率统计组.正交设计法[M].北京:石油化学工业出版社,1976..
  • 8NFPA 1971,Standard on Protective Ensemble for Structural Fire Fighting 2000 Edition[S].
  • 9LI Jun, LBARKER R, DEATON A S. Effects of Material Combinations on Heat Loss of Firefighter Turnout Clothing Evaluated by an Advanced Sweating Manikin[C]// Proceedings of the Textile Institute's 83rd World Conference. Shanghai: Donghua University Press, 2004 : 878 - 883.
  • 10李俊,王云仪,张向辉,王晓琼,韩嘉珅.消防服多层织物系统的组合构成与性能[J].东华大学学报(自然科学版),2008,34(4):410-415. 被引量:36

共引文献59

同被引文献172

引证文献20

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部