针对静态加热式空气源热泵热水机(器)能效比不断提高,根据热泵系统的工作原理和结构特点,通过对热泵系统热力循环的各个过程的分析计算,提出空气源热泵热水机提高能效比的方向和解决措施,为热泵热水机(器)行业产品的升级和技术发展提供参考和借鉴。
Declaration the development trend of increasing the COP of air-source static heat pump water heater,through calculation and analysis of the working principle and structure characteristics of heat pump water heater,to proposed research topic and the solutions to improve the COP,to provide reference for the technology development of heat pump water heater and industry upgrading.