摘要
为实现某核电站放射性碘废气处理系统活性炭吸附剂的国产化,选取国产圆柱状煤质活性炭与椰壳活性炭,以一定比例混合,浸渍烘干,装填到碘废气处理系统中,现场试验结果表明其阻力≤3 400 Pa、除碘效率≥98%,性能满足工程使用要求。
For the purpose of the indigenization of activated carbon adsorbent at a nuclear plant, two types of activated carbons were mixed at the optimum rate, through impregnating and drying. The onsite testing results show that the resistance of the mixed activated carbon is ≤ 3 400 Pa and the efficiency of cleaning radioactive methyl iodine is ≥ 98 %. The other performances meet the needs of engineering.
出处
《辐射防护通讯》
2013年第5期38-40,共3页
Radiation Protection Bulletin
关键词
核电站
放射性碘废气处理系统
活性炭吸附剂
国产化研究
Nuclear plant
Radioiodine waste gas treatment system
Activated carbon adsorbent
Indigenization of research