期刊文献+

过硫酸钾氧化偶氮荧光桃红催化光度法测定痕量银 被引量:9

Catalytic Spectrometric Determination of Trace Silver Via Using Oxidation of Azophloxine with Potassium Persulfate
下载PDF
导出
摘要 以过硫酸盐氧化偶氮类试剂催化动力学法测定银,多数线性范围较窄、选择性欠佳。本文建立了以偶氮荧光桃红作指示物质、α,α′-联吡啶作活化剂的催化光度法,测定痕量银检出限为1.0×10-4μg/mL,线性范围2.0×10-4~4.0×10-2μg/mL,灵敏度高,选择性好。用于测定鄂铜矿中银,结果满意。采用自装的微机动力学数据处理系统,测试简便、准确。 Based on the catalytic effect of Ag(Ⅰ) on the oxidation of azophloxine with potassium per-sulfate in the presence ofα,α' -bipyridyl as an activator, a new catalytic spectrophotometric method for determining trace amounts of Ag(Ⅰ) is studied. The limit of detection for Ag is 1. 0×10-4μg/ mL. The linear range of determination of silver is 2. 0×10-4~4. 0×102 μg/mL. The method has been used to determine trace Ag in ores with satisfactory results.
作者 郑肇生 凌琳
机构地区 福州大学化学系
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 1991年第4期462-463,共2页 Chemical Journal of Chinese Universities
关键词 催化 比色法 过硫酸盐 氧化偶氮 Catalysis, Spectrophotometry, Silver
  • 相关文献

参考文献1

  • 1王耀光,分析化学,1988年,16卷,8期,757页

同被引文献1330

引证文献9

二级引证文献71

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部