针对锦西天然气化工有限责任公司合成氨装置低温变换炉运行状况,分析引起低温变换催化剂失活的原因,阐述在低温变换炉前增加脱氯装置的技术改造,总结分析改造效果。
The operation condition of low temperature shift converter in Jinxi Natural Gas Chemical In- dustry Co., Ltd. was reviewed. Reasons for catalyst deactivation were studied. A technical reformation plan that added a dechlorination unit before shift converter was presented. You may find the reformation results and the analysis in this paper.