摘要 目的研究受检者在全身18F-FDG PET/CT显像中所受到的辐射有效剂量。方法选取58例全身PET/CT显像的受检者,在自动曝光技术下通过公式估算出CT和PET的全身有效剂量,并将估算结果与传统放射检查(常规CT、X线、99mTC核素显像)相比较。结果单次全身PET/CT显像受检者所接受的CT有效剂量为2.4~6.8mSv,平均(4.3±2.2)mSv,PET有效剂量为4.2~6.3 mSv,平均(5.5±1.5)mSv;PET/CT总有效剂量为6.6~13.1mSv,平均(9.8±3.3)mSv。其辐射总有效剂量与一次腹部或盆部常规CT扫描所产生的辐射剂量相当。结论单次全身PET/CT检查受检者所接受的辐射剂量是安全的。 Objective To evaluate the effective radiation dose in patients undergoing whole- body 18F_FDG PET/CT examinations. Methods Whole-body PET/CT was performed in 58 sub- jects. The effective radiation dose of PET/CT was estimated by using the conversion formula with automatic exposure control technique. The estimated results were compared with conventional ra- diography (conventional CT,X-line or 99mwc scintigraphy). Results The mean dose was (4. 3± 2.2)mSv(range,2.4 to 6.8 mSv) in CT and (5.5±1.5)mSv( range,4.2 to 6.3 mSv) in PET at one time. The total effective dose of PET/CT examinations was (9.8 ± 3.3)mSv ( range, 6.6 to 13.1 mSv). Its total effective radiation dose equivalent to a conventional CT scan of belly or basin produced dose. Conclusion One-time whole-body PET/CT is safe for subjects due to the low radiation dose.
出处 《南昌大学学报(医学版)》 CAS 2013年第10期44-46,共3页 Journal of Nanchang University:Medical Sciences
关键词 PET CT 辐射剂量 有效剂量 PET/CT radiation dose effective dose
  • 相关文献

参考文献11

  • 1全国PET/CT(PET)配置与使用情况调查简报[J].中华核医学杂志,2009(4):282-283. 被引量:30
  • 2Michael J, Gelfand L, Marguerite T, et al. Pediatric radiophar maceutical administered doses: 2010 North American Consen sus Guidelines[J]. J Nucl Med ,2011,52(2) :318-322.
  • 3Mc Nitt G. Radiation dose in CT [J]. Radiographics, 2002,22 1541-1553.
  • 4CEC Quality criteria for computed tomography. European guide- lines,EUR 16262[M]. Luxembourg :Commission of the Euro- pean Communities, 1999 : 70.
  • 5Khursheed A, Hillier M C, Shrimpton P C, et al. Influence of patient age on normalized effective doses calculated for CT ex- aminations[J]. Br J Radiol, 2002,75: 819-830.
  • 6Valentin J. Radiation dose to patients from radiopharmaceuti- cals( addendum 2 to ICRP publication 53) ICRP publication 80 approved by the Commission in September 1997 [J]. Ann ICRP,1998,28:1.
  • 7陈伟,王德忠,李传琛.PET中心患者源项的辐射防护优化研究[D].上海交通大学,2011.
  • 8Huang B, Law W M,Khong P L. Whole body PET/CT scan- ning:estimation of radiation dose and cancer risk[J]. Radiolo- gy,2009,251(1) : 166-174.
  • 9Leide Svegborn S. ladition exposure of patients and personnel from a PET/CT procedure with 18F-FDG[J]. Radiat Prot Do- simetrv, 2010,139:208-213.
  • 10中华人民共和国国家质量监督检验检疫总局.GBl8871-2002电离辐射防护与辐射源安全基本标准[S].秦皇岛:中国标准出版社,2003.

二级参考文献1

共引文献31

同被引文献79

  • 1罗敏,高源统,彭文献,虞希祥,李永畴.扩散加权序列动态评估原发性肝癌疗效的应用价值[J].放射学实践,2011,26(1):55-58. 被引量:13
  • 2王立东.河南食管癌研究的理解和思考[J].郑州大学学报(医学版),2006,41(1):1-5. 被引量:30
  • 3卓水清,陈林,张福君,赵明,张亮,刘健,李奎,吴沛宏,郑庆生,王琰.^(125)I放射性粒子植入术后患者周围辐射剂量的监测[J].癌症,2007,26(6):666-668. 被引量:67
  • 4中华人民共和国国家质量监督检验检疫总局.GBl8871-2002电离辐射防护与辐射源安全基本标准[S].北京:中国标准出版社,2003.
  • 5Wang Q,Zhao X,Song J,et al.The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT):A phantom study[J].J Xray Sci Technol,2013,21(4):453-464.
  • 6Sub YJ,Kim YJ,Hong SR,et al.Combined use of automatic tube potential selection with tube current modulation and iterative reconstruction technique in coronary CT angiography[J]. Radiology,2013,269(3):722-729.
  • 7Mulkens TH,Bellinck P,Baeyaert M,et al.Use of an automatic exposure control mechanism for dose optimization in multi- detector row CT examinations clinical evaluation[J].Radiology, 2005,237(1):213-223.
  • 8McCollough CH,Bruesewitz MP,,Kofler JM Jr.CT dose reduction and dose management tools:overview of available options [J].Radiographics,2006,26(2) :503-512.
  • 9Dawson P,Morgan J.The meaning and significance of the equilibrium phase in enhanced computed tomography of the liver[J].Br J Radiol, 1999,72(857) :438-442.
  • 10Kalra MK,Pradas S,Saini S,et al.Clinical comparison of standard- dose and 50% reduced-dose abdominal CT:Effect on image quality[J].AJR AmJ Roentgenol,2002,179(5):l101-1106.

引证文献8

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部