摘要 防止绝缘受潮是变压器现场处理的关键环节,目前主要采用的热油循环法仍存在效率低、处理时间长等不足,尤其在低温环境下,受设备功率制约,无法达到预期加热目标,影响绝缘处理效果。对低频条件下短路加热技术进行专门研究,利用绕组短路损耗从设备内部加热,提高了加热效率,同时设计研发专门的低频加热装置,可在变电站现场长时间稳定运行。通过实地加热试验验证,证明此装置的有效性。 To avoid the moisture in transformer insulation is the key step in treating the outdoor transformer. Nowadays the method of circular hot-oil is inefficiency. If the air temperature is low, the heating effect can't be got. The paper studies the technology of heating the transformer coil in short-circuit. The transformer can be heated by the loss from inner tanker, which can raise heating efficiency. Moreover, a low frequency device for heating is developed which can be used in substation. The experiment proved that the device can raise the heating efficiency.
出处 《陕西电力》 2013年第12期89-93,98,共6页 Shanxi Electric Power
基金 陕西省电力公司科研项目(5226KY100011)
关键词 变压器 加热装置 短路法 低频 transformer heating device short-circuit method low frequency
  • 相关文献

参考文献9

二级参考文献30

  • 1王秀春,杨增军,毛一之,孙新中,智会强,韩鹏.自然冷却高燃点油变压器温升计算方法[J].中国电机工程学报,2004,24(7):223-226. 被引量:21
  • 2孙恒锋.油箱感应加热和零序短路电流加热综合真空干燥变压器一例[J].变压器,1994,31(2):32-34. 被引量:3
  • 3路长柏 朱英浩 等.电力变压器计算[M].哈尔滨:黑龙江科学技术出版社,1990..
  • 4水利电力部华中电业管理局.大型变压器现场检修工艺规程(华中电管局技术资料)[M].武汉,1984..
  • 5赵家礼.变压器故障诊断与修理[M].北京:机械工业出版社,2000..
  • 6Karsai K, Kerenyi D, Liss L. Large Power Transformers [M]. Amsterdam, The Netherlands: Elserier, 1987.
  • 7徐国政,李庆民,张节容.自冷式气体绝缘变压器温升分布的计算方法[J].中国电机工程学报,1997,17(2):102-108. 被引量:7
  • 8Martin J H. The J & P transformer book twelfth edition[M]. Oxford: Reed Educational and Professional Publishing Ltd, 1998: 681-690.
  • 9吉林省送变电工程公司编写组.电力变压器安装[M].北京:水利电力出版社,1977:362-385.
  • 10全国高电压试验技术标准化分技术委员会.DL/T664-2008带电设备红外诊断技术应用导则[S].北京:中国电力出版社,2008.