期刊文献+

不同血管条件下的血管机器人外流场对比分析 被引量:1

Comparative analysis of flow field outside the robots under the different blood vessels
下载PDF
导出
摘要 采用流固耦合技术,对比弹性血管和刚性血管对血管机器人外流场参数,为血管机器人外结构参数设计提供参考.对比分析发现,刚性壁模型中的血液压力比弹性壁模型的变化幅度大,在刚性壁模型中,下游形成一个速度较高的回流区域;而弹性壁模型中,下游分离成两速度较高区域.刚性壁模型对血液的扰动强度高一些,且幅度略大,而弹性壁模型的壁面剪切应力变化范围比刚性壁模型的略大. Fluid-structure interaction (FSI) technolo~ is used to compare to the flow field parameters outside the vascular robot between under the rigid vessel and elasticity vessel, and to provide a reference for design of the outer structure parameters of the vascular robot. Comparative analysis found that the variation amplitude of pressure in rigid blood wall model is greater than that in the elastic wall model. In the rigid wall model, the re- circulation region of a higher speed will be formed at downstream, the disturbance intensity of the blood flow is higher, and the amplitude is slightly larger; while the higher speed downstream is separated into two regions in the elastic wall model, and the wall shear stress varies slightly larger in the elastic wall model than that in the rigid wall model.
出处 《广州大学学报(自然科学版)》 CAS 2013年第6期59-63,共5页 Journal of Guangzhou University:Natural Science Edition
基金 国家自然科学基金资助项目(51205072) 广州市属高校科技计划资助项目(2012A084)
关键词 血管机器人 外流场 弹性血管 刚性血管 流固耦合分析 vascular robots flow field elasticity vessel rigid vessel fluid-structure interaction analysis
  • 相关文献

参考文献10

  • 1MOLONY D S,CALLANAN A,KAVANAGH E G. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft[J].Biom Eng Online,2009.24-27.
  • 2TREMMEL M,XIANG J,NATARAJAN S K. Alteration of intra-aneurismal hemodynamics for flow diversion using enterprise and vision stents[J].World Neuro,2010,(2/3):306-315.
  • 3FENG G,HIROSHI U,LI G. Fluid structure interaction simulation in three-layered aortic aneurysm model under pulsatile flow:Comparison of wrapping and stenting[J].{H}Journal of Biomechanics,2013,(07):1335-1342.
  • 4闫亭亭,刘芳芳,陈雪,乔爱科.三角形截面丝裸支架治疗梭形颅内动脉瘤的流固耦合数值模拟研究[J].生物医学工程学杂志,2012,29(5):867-871. 被引量:3
  • 5曾堃,乔爱科.三种截面支架对动脉瘤血流动力学影响的比较研究[J].医用生物力学,2012,27(2):220-226. 被引量:9
  • 6PEDLEY T J. The fluid mechanics of large blood vessels[M].{H}Cambridge,UK:Cambridge University Press,1980.
  • 7PONTRELLI G. The role of the arterial priestess in blood flow dynamic[J].{H}Medical Engineering & Physics,2006,(01):6-12.
  • 8JIANG F,YU J,LIANG Z W. New blood vessel robot design and outside flow field characteristic[J].Appl Mech Mater,2010,(29/32):2490-2495.
  • 9JIANG F,YU J,WANG Y J. Influence of contractive and dilative motion of blood vessel to robot[J].Adv Mat Res,2010,(139/141):881-884.
  • 10江帆;黄鹏.Fluent高级应用与实例分析[M]{H}北京:清华大学出版社,2008.

二级参考文献8

共引文献10

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部