期刊文献+

MK1附着体义齿返修13例原因及改良修复方式分析

The reasons why 13 MK1 attachment were re-fabricated and some methods for improvement
下载PDF
导出
摘要 目的:探讨MKl附着体义齿修复病例返修的原因及改良修复方式分析。方法:对MKl附着体义齿修复的13例返修病例,分别从力学和义齿制作工艺角度分析返修的原因。结果:返修的原因中,部分是由于MKl附着体自身设计的限制,部分因技术引进,初期经验不足,对义齿设计和制作环节中的技术关键有所忽略所致;针对返修病例做出相应改进,随访1~1.5a后效果良好。结论:临床使用MKl附着体时,修复医师应熟练掌握MKl附着体的特征和适应证,加强医患沟通;对患者及时随访,提高MKl附着体义齿修复的成功率。 PURPOSE: To investigate the reasons why 13 MK1 attachment were re-fabricated and to suggest some improvement methods. METHODS: Mechanics and denture production technology were reviewed in 13 cases with MK1 attachment denture to determine the causes of failure. RESULTS: In some cases, MK1 attachments were poorly designed, while in other cases problems were found during denture design and production process due to limited experiences at the initial stage. MK1 attachments were re-done based on the specific cause and the outcome was good after 1-1.5 years of follow-up. CONCLUSIONS: When using MK1 attachment, prosthodontists should be familiar with the characteristics and indications of MK1 attachment. Meanwhile, we should strengthen doctor-patient communication and follow up patients timely to improve the success rate of MK1 attached denture repair.
出处 《上海口腔医学》 CAS CSCD 北大核心 2013年第6期715-717,共3页 Shanghai Journal of Stomatology
关键词 MK1附着体 游离端牙缺失 可摘局部义齿 MK1 attachment Distal extension defect Removable partial denture
  • 相关文献

参考文献11

二级参考文献47

  • 1吴建华,徐卫华.金属烤瓷冠桥颈缘的临床应用技术分析[J].贵阳医学院学报,2001,26(4):351-352. 被引量:1
  • 2马绪臣,张刚,陈后金,吴湘琪,曹采方,邹兆菊.牙根尖X线片数字减影技术的临床应用价值[J].中华口腔医学杂志,1995,30(6):323-325. 被引量:4
  • 3张壁,程祥荣,钱法汤.金属-烤瓷联合全冠在口腔修复科的应用[J].口腔医学纵横,1996,12(1):54-55. 被引量:22
  • 4徐君伍主编.口腔修复学 第3版[M].北京:人民卫生出版社,1993.23.
  • 5[1]Bates J F. Studies on the retention of cobah-chiomium partial dentures. Br Dent J , 1968, 125: 98~100.
  • 6[2]Lehmann KM. and Arnim FV. Studies on the retention forces of snap-on attachments. Quintessence Dent Technol , 1978,7:45 ~47.
  • 7[3]Yoshimatsu N. Study on the exeractive strength of the human teeth. In Yamada, H., editor: Strength of Biologic materials. Baltimore, 1970, The Williams &Wilkins Co.154.
  • 8[7]Stewart BL. Edwards R.O., Retention and wear of precision-type attachments . J Prosthet Dent , 1983, 49:28~34.
  • 9[8]Robert E. Extracoronal attachments. Dent Clin North Am,1985,29:185~198.
  • 10[9]Vermeulen A, Keltjens H, van't Hof M. Ten-year evaluation of removable partial dentures: Survival rates based on retreatment, not wearing and replacement .J Prosthet Dent , 1996, 76:267~272.

共引文献107

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部