摘要 室内确定了一种适用于热采井(井深约2000 m,蒸汽驱时温度为350℃)的抗高温低密度水泥浆体系。该水泥浆体系密度在1.40—1.60 g/cm^3之间可调;失水量低;低温(40℃)养护后,早期强度大于15 MPa,远高于一般的低密度水泥浆体系;高温(350℃)养护后,水泥石强度仍大于10MPa,体现了其优异的抗高温强度衰退性能。同时对该体系的降失水、调凝、增加早期强度和抗高温的作用机理作了初步的探讨。 A high temperature tolerable lightweight cement slurry system is designed for heated recovery well with depth of 2000m, and temperature as high as 350 C during steam flooding. The density of this system is adjustable between the range of 1. 40 to 1. 60 g/cm3, with low filtration. Its early strength reaches as high as 15 MPa after aging at 40 C, and after aging in 350 C environment, its strength remains over 10 MPa. The mechanism on its fluid loss reducing, thickening adjustment, early strength improvement and high temperature tolerance are also investigated.
出处 《钻井液与完井液》 CAS 2000年第5期17-20,共4页 Drilling Fluid & Completion Fluid
关键词 热采油井 低密度水泥浆 水泥浆添加剂 固井 lightweight cement cement slurry cement additive high temperature
  • 相关文献

参考文献7

  • 1佟曼丽等.油田化学.西南石油学院,1988.
  • 2EilersLH,NelsonEB,MoranLK.High-temperaturecementcomposition-pectolite,scawtite,truscotliteorxonotlite:Whatdoyouwant?.JPT,1983,6:1373-1377
  • 3ErikBNelson.ImprovedcementslurrydesignnedforthermalEORwells.OGJ,1986,12:39-44
  • 4JohnsonCE,etal.APIworkgroupreportfieldtestsofgeothermalcements.OGJ,1985,2:93-97
  • 5FarouqSM,MeldauRF.Currentsteamfloodtechnology.JPT,1979,10;1332
  • 6Thedevelopmentofalow-costthermallystablepolymer/surfactantsystemforsteam-sweepefficiencyimprovement.SPE24032
  • 7DwightKSmith.Sillicaflour-mechanismforimprovingcementingcompositionforhigh-temperaturewellconditions.SPE1980;12:43-48

共引文献1

同被引文献51

引证文献4

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部