分析了预焙阳极5点取样法的局限性,提出了一种新的预焙阳极取样方法,即9点取样法,经过实际应用取得了良好效果,仅供同行业参考。
This paper analyzes the limitations of five points sampling method for prebaked anode, and a new kinds of prebaked anode sampling method was put forward,which is nine points sampling method. A good effect was achieved during the practice, which could provide the reference for the carbon industry.
出处
《炭素技术》
CAS
北大核心
2013年第6期33-35,共3页
Carbon Techniques
关键词
预焙阳极炭块
取样
5点取样法
9点取样法
Prebaked anode carbon block
sampling
five points sampling method
nine points sampling method