介绍了南昌卷烟厂空调系统技术改造的情况。新空调系统采用风机变频调速实现变风量运行 ,并通过自动控制系统实现多工况分区节能控制 ,采用滤筒式高效过滤器替代原有的过滤器。通过空调系统的技术改造 ,改善了车间的温度、湿度状况 。
Technological renovation of the air-conditioning system in Nanchang Cigarette Plant was introduced Flexible wind\|rate can be realized in this new air\|conditioning system after using frequency controlled wind turbine.And with the use of automatic control system,multi\|operation mode partitioned control for energy\|saving was implemented.The filter was also replaced by a high\|efficiency filter drum.With the above renovations,temperature and humidity can be better controlled,and the system can run energy\|efficiently.