期刊文献+

两种检测系统测定糖化血红蛋白的比对分析 被引量:1

Analyses and comparison of two assay systems for glycosylated hemoglobin measurement
下载PDF
导出
摘要 目的对两种检测系统测定糖化血红蛋白所得结果进行相关性分析及偏倚评估。方法分别使用TOSOH G8糖化血红蛋白分析仪采用离子交换高效液相色谱法(HPLC)和雅培AEROSET全自动生化分析仪以酶化学法检测40例血液样本的糖化血红蛋白,对两检测系统的结果进行比对分析,检查离群点,计算线性相关系数、直线回归方程和预期偏倚评估。结果离子交换高效液相色谱法(TOSOH G8糖化血红蛋白分析仪)的测定均值为7.31%,酶化学法(雅培AEROSET生化仪)的测定均值为7.07%,线性回归方程为Y=1.047 4 X-0.587 2,r2=0.954 4,糖化血红蛋白可接受偏倚大于预期偏倚可信区间上限。结论酶化学法与离子交换高效液相色谱法结果相当,酶化学法结果可接受,可满足临床要求。 Objective To evaluate two kinds of assay systems for glyeosylated hemoglobin measurement. Methods Ion-ex- change high performance liquid chromatography(HPLC) by TOSOH G8 glycosylated hemoglobin analyzers and enzyme chemistry method by Abbott AEROSET automatic biochemical analyzer were applied to test glycosylated hemoglobin in 40 cases of blood sample. The results went through comparative analysis, the outlier checking, the linear correlation coefficient calculating, getting ex- pected bias estimation of linear regression equation. Results The determination averages was 7.31% by HPLC(TOSOH G8 glycat- ed hemoglobin analyzers) and 7.07 % by enzyme chemistry method(Abbott AEROSET biochemical Analyzer). The linear regres- sion equation was Y= 1. 0474X--0. 5872 ,R^2 = 0. 954 4, and glycosylated hemoglobin acceptable bias was greater than the upper lim- it of expected bias confidence interval. Conclusion Glyeosylated hemoglobin results by enzyme chemical method is equivalent to ion- exchange high performance liquid chromatography which means enzyme chemistry method is acceptable to meet the clinical require- ment.
出处 《国际检验医学杂志》 CAS 2014年第1期90-91,113,共3页 International Journal of Laboratory Medicine
关键词 血红蛋白A 糖基化 色谱法 高压液相 实验室技术和方法 hemoglobin A,glycosylated chromatography,high pressure liquid laboratory techniques and procedures
  • 相关文献

参考文献9

  • 1Francesco DATI;Metzmann E;潘柏申.蛋白质实验室检测项目临床应用指南[M]上海:上海科学技术出版社,2008398.
  • 2National Committee for Clinical Laboratory Standards. Method comparison and biss estimation using patient.samples:approved guideline[S].NCCLS,2002.
  • 3余玲丽,赵莹,吴建平.糖化血红蛋白两种检测方法的比对[J].实验与检验医学,2009,27(5):487-488. 被引量:6
  • 4American Diabetes Association. Standards of medical care for patients with diabetes mellitus[J].DIABETES CARE,2003,(01):33-50.
  • 5Word Health Organization. Use of glycated hemoglobin(HbA1c) in the diagnosis of diabetes mellitus:abbreviated report of a WHO consultation[M].Geneva,2011.22-25.
  • 6Hadjadj S,Duengler F,Barriere M. Determination of HbAlc concentrations in patients with cute myocardial infarction:comparison of the DCA2000 device with the HPLC method[J].Diabetes & metabolism,2005,(03):290-294.
  • 7阮绍均.高压液相层析法与酶法检测糖化血红蛋白的比较[J].实验与检验医学,2009,27(5):465-466. 被引量:16
  • 8肖弘,王敏,李小盛.离子交换高效液相层析法与酶化学法测定糖化血红蛋白的比对分析[J].检验医学,2010,25(11):888-890. 被引量:14
  • 9Liu L,Hood S,Wang Y. Direct enzymatic assay for% HbA1C in human whole blood samples[J].CLINICAL BIOCHEMISTRY,2008,(7/8):576-583.

二级参考文献15

  • 1崔建娇,朱勇,贾勇,史际华,桂晓巍.两种测定糖化血红蛋白的方法学比较[J].实用医技杂志,2006,13(4):566-566. 被引量:7
  • 2King H, Aubert RE, Herman W H.Global burden of diabetes, 1995- 2025: prevalence,numerical estimates, and projection[J]. Diabetes Care, 1998,21:1414-1431.
  • 3The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long--term complications in insulin-dependent diabetes mellitus[J]. N Engl J Med, 1993,329:977-986.
  • 4Goldstein DE, et al. Test of glycemia in diabetes[J]. Diabetes Care. 2004,27(7): 1761 - 1773.
  • 5National Committee for Clinica/laboratory Standards. Method comparison and bias estimation using patient samples [S]. Approved Guideline, EP9-A2,Pennsylvania, NCCLS, 2002.
  • 6John WG.Glycated haemoglobin analysis[J].Ann Clin Biochem,1997,34(Pt 1):17-31.
  • 7National Committee for Clinical Laboratory Standards.Method comparison and biss estimation using patient samples:approved guideline[S].EP9-A2,NCCLS,2002.
  • 8National Committee for Clinical Laboratory Standards.Evaluation of precision performance of clinical chemistry devices;approved guideline[S].EP5-A,NCCLS,1999.
  • 9Liu L,Hood S,Wang Y,et al.Direct enzymatic assay for %HbA1C in human whole blood samples[J].Clin Biochem,2008,41(7-8):576-583.
  • 10Frank EL,Moulton L,Little RR,et al.Effects of hemoglo-bin C and S traits on seven glycohemoglobin methods[J].Clin Chem,2000,46(6 Pt 1):864-867.

共引文献27

同被引文献3

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部