摘要
结合武昌船舶重工有限责任公司制造的一系列海洋工程船的推进装置电动机的启动方案,总结船用交流大功率电动机的启动方式,比较自耦变压器、软启动和变频启动方式的优缺点及应用范围。
According to the starting plans of the thruster motors for the offshore supply vessels built in Wuchang Shipbuilding Industry Company Limited, the starting methods of marine AC high - power motor was summarized. The advantages, disadvantages and application range of the starting methods of auto-transformer, soft starting and frequency converter were comparative analyzed.
出处
《船海工程》
2013年第6期164-166,共3页
Ship & Ocean Engineering
关键词
海洋工程船
电动机
自耦变压器
软起动
变频起动
offshore support vessel
motor
auto-transformer
soft starting
frequency converter