期刊文献+

城市变电站软弱地基换填垫层法处理技术

Treatment technology of replacement cushion for soft foundation in city substation
下载PDF
导出
摘要 六盘水市110 kV某新建城市变电站,站址位于六盘水市钟山区,场地多为淤泥或杂填土,厚度在0 m到3 m之间,为明显的软弱土地基,现以该变电站地基处理方案为例,讨论城市变电站软弱地基换填垫层法处理技术。 A new city 110kV substation was constructed in Liupanshui, located in Zhongshan district of Liupanshui. The field was full of silt and miscellaneous fill, which was soft foundation with the thickness of 0 to 3m. The paper discussed the treatment technology of replacement cushion for soft foundation in city substation, with this treatment plan as an example.
作者 余子剑
出处 《贵州电力技术》 2014年第1期43-44,53,共3页 Guizhou Electric Power Technology
关键词 变电站 软弱地基 换填垫层法 substation soft foundation replacement cushion