摘要 随着CT机软硬件的不断更新和发展, 无创的多层螺旋CT冠状动脉血管成像检查技术在临床实践中得到广泛应用,已成为早期筛查和诊断冠心病的重要检查方法[1].在冠状动脉血管成像检查中,患者的呼吸、心率、身高、体质量,造影剂的浓度、剂量、注射的速度等,均可以影响图像的质量.而冠状动脉血管成像的图像质量直接影响冠心病的早期筛查和诊断.造影剂的浓度对冠状动脉血管成像的影响越来越重要[2].本研究旨通过应用宝石CT 在冠状动脉成像中的优势, 探讨不同造影剂对冠状动脉血管成像的影响,以达到合理使用造影剂的目的.
出处 《中国药物与临床》 CAS 2014年第1期46-48,共3页 Chinese Remedies & Clinics
基金 山西医科大学第二医院院内基金(20120204)
  • 相关文献

参考文献11

  • 1Mollet-Nico R,Cademartiri F,van Mieghem CA. High-reso-lution spiral computed tomography coronary angiography in pa-tients referred for diagnostic conventional coronary angiography[J].{H}CIRCULATION,2005.2318-2323.
  • 2Husmann L,Alkadhi H,Boehm T. Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography[J].{H}European Radiology,2006.1111-1116.
  • 3Ho LM,Nelson RC,Delong DM. Determining contrast medium dose and rate on basis of lean body weight:does this strategy improve patient-to-patient uniformity of hepatic en-hancement during multi-detector row CT[J].{H}RADIOLOGY,2007,(02):431-437.
  • 4Ferencik M,Lisauskas JB,Cury RC. Improved vessel mor-phology measurements in contrast-enhanced multi-detector com-puted tomography coronary angiography with non-linear post-pro-cessing[J].{H}EUROPEAN JOURNAL OF RADIOLOGY,2006,(03):380-383.
  • 5Moselewsk F,Ropers D,Pohle K. Comparison of measure-ment of cross-sectional Coronary atberosclerotic plaque and ves-sel areas by 16-slice multidetector computed tomography versus intravascular ultrasound[J].{H}American Journal of Cardiology,2004,(10):1294-1297.
  • 6Bae KT,Seeck BA,Hildebolt CF. Contrast enhancement in cardiovascular MDCT:effect of body weight,height,body sur-face area,body mass index,and obesity[J].{H}AMERICAN JOURNAL OF ROENTGENOLOGY,2008.777-784.
  • 7Cademartiri F,Mollet NR,Runza G. Influence of intracoro-nary attenuation on coronary plaque measurements using multi-slice computed tomography:observations in an ex vivo model of coronary computed tomography angiography[J].{H}European Radiology,2005.1426-1431.
  • 8Choi SI,George T,Schuleri KH. Recent development in wide-detector computed tomography[J].Int J Cardiovascular Imaging,2009.23-29.
  • 9Annemarieke R,Matthijs F,Alexander M. Biphasic contrast medium injection in cardiac CT:moderate versus high concen-tration contrast material at identical iodine flux and iodine dose[J].{H}European Radiology,2010,(08):1917-1925.
  • 10Behrendt FF,Mahnken AH,Stanzel S. Intraindividual com-parison of contrast media concentrations for combined abdominal and thoracic MDCT[J].{H}AMERICAN JOURNAL OF ROENTGENOLOGY,2008.145-150.