CRH380BL动车组侧门系统典型故障分析及解决方案 被引量:9

Typical Fault Analysis and Solution of CRH380BL EMU Side-Door System
下载PDF
导出
摘要 针对CRH380BL动车组侧门系统在运营中出现的门反复开关、门无法打开、站台补偿器未自动收回等典型故障进行分析,发现门反复开关是由于98%限位开关的安装位置不准确导致、门密封胶条润滑不良导致门无法打开、站台补偿器节流阀内大量的油脂致使气路堵塞补偿器渡板无法收起.分别通过更新工艺文件、更改门控器控制逻辑、科学合理安排润滑周期和更换优质气动元器件等措施,彻底根治了上述故障. Focused on the typical faults of CRH380BL side-door system, during repeated open and close, failure of open, gap filler fail to pull-back, it is found that repeated open and close of the door is due to the inaccurate installation location of the 98% limit switch, that the doors can not be opened due to poor lubrication of the door sealing strip, and that the air compensator transition board can not be pulled back due to the site compen- sator throttle blocked by excess grease. Reasonable arranged lubrication cycle, replaced high-quality pneumatic components and other measures are taken to eradicate the above failures by updating process file and changing door controller control logic.
出处 《大连交通大学学报》 CAS 2014年第1期100-103,共4页 Journal of Dalian Jiaotong University
关键词 侧门系统 故障 查找 改进 side-door system fault find out solution