摘要 噪声是影响无缝钢管超声检测精度的最主要的因素,在利用超声波无缝钢管检测中受到车间环境与检测设备的影响,检测端的接收信号信噪比较低,使无缝钢管的缺陷判别出现误判与漏判。提出基于粒子群优化消噪技术的无缝钢管超声波检测技术,分析脉冲式超声波无缝钢管检测中的回波模型,结合粒子群优化技术的全局与局部搜索能力对回波信号的有用成分提取,并且在检测中引入粒子变异方法防止信号提取中陷入局部最小。实验证明,这种方法能够在脉冲式超声波无缝钢管检测中有效降低回波的噪声,大大提高检测的准确率,具有很强的实用性。 Based on particle swarm optimization de-noising technology of seamless steel pipe uhrasonic detection technology, analysis of the pulse ultrasonic seamless steel pipe detection of echo model, combined with particle swarm optimization techniques for global and local search capability of the echo signal of useful components extraction, and in the detection of the introduction of particle variation method for preventing signal extraction of falling into local minimum. The experiment proves, this method can in pulsed ultrasonic seamless steel pipe detection effectively reduce echo noise, greatly improve the detection accuracy rate, strong practicality.
作者 石晓林
机构地区 吉林工商学院
出处 《科技通报》 北大核心 2013年第12期48-50,54,共4页 Bulletin of Science and Technology
基金 国家自然科学基金(78963206)
关键词 超声检测 无缝钢管 粒子群消噪 粒子变异 ultrasonic inspection seamless steel tubei particle swarm demising particle variation
  • 相关文献

参考文献3

二级参考文献11

  • 1蒋危平.超声波探伤仪及数字化超声波探伤仪[J].无损检测,1997,19(2):55-59. 被引量:16
  • 2[1]MUKHOPADHYAY S,SRIVASTAVA G P.Characterisation of metal loss defects from magnetic flux leakage signals with discrete wavelet transform[J].NDT&E International,2000,33:57-65.
  • 3[2]LEE J Y,AFZAL M,UDPA S,UDPA L,MASSOPUST P.Hierarchical rule based classification of MFL signals obtained from natural gas pipeline inspection[A].Neural Networks,2000. Proceedings of the IEEE-INNS-ENNS International Joint Conference[C].2000,5:71-76.
  • 4[3]HWANG K,MANDAYAM S,UPDA S S,UPDA L,LORD W,ATZAL M.Characterization of gas pipeline inspection signals using wavelet basis function neural networks[J].NDT&E International, 2000,33:531-545.
  • 5[4]SEPULVEDA N G,THOMAS I M,WIKSWO J P,Jr..Magnetic susceptibility tomography for three-dimensional imaging of diamagnetic and paramagnetic objects[J].IEEE Transactions on Magnetics,1994,34:5062-5069.
  • 6[5]MINKOV D,SHOJI T.Method for sizing of 3-D surface breaking flaws by leakage flux[J].NDT&E international,1998,31(5):317-324.
  • 7王子诚.全数字式超声波探伤仪的发展[J].中国锅炉压力容器安全,1998,14(6):35-36. 被引量:1
  • 8朱景清,傅晨光,刘宏宇,陈维津,李小龙,田永良,郭兆成.连铸圆管坯的质量及其控制(上)[J].钢管,2003,32(1):14-20. 被引量:11
  • 9朱景清,傅晨光,刘宏宇,陈维津,李小龙,田永良,郭兆成.连铸圆管坯的质量及其控制(下)[J].钢管,2003,32(2):13-16. 被引量:7
  • 10蒋危平.无损检测仪器的计算机化[J].无损检测,1992,14(1):1-2. 被引量:5

共引文献53

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部