期刊文献+

A Method for Eliminating the Impact of Microwave Sweeper Power Fluctuation in BOTDA System 被引量:2

A Method for Eliminating the Impact of Microwave Sweeper Power Fluctuation in BOTDA System
原文传递
导出
摘要 在 BOTDA 系统的微波 sweeper 电源变化的影响理论上被分析了并且试验性地测试了。并且把探查波浪电源的即时获得与一个新算法作比较为消除这影响认识到探查波浪电源正规化的一个新奇方法被建议。建议方法的原则理论上被描述。并且在我们的新方法和常规方法之间的对比测试被执行。实验结果显示温度精确性有效地被改进从 ? The impact of microwave sweeper power fluctuation in the BOTDA system has been theoretically analyzed and experimentally tested. And a novel method comparing real-time acquisition of probe wave power with a new algorithm to realize probe wave power normalization for eliminating this impact was proposed. The principle of the proposed method was described theoretically. And the contrast test between our new method and conventional one was carried out. The experiment results indicated that the temperature accuracy was effectively improved from +5 C to 2 C.
出处 《Photonic Sensors》 SCIE EI CAS 2014年第1期86-91,共6页 光子传感器(英文版)
关键词 电源波动 系统 微波 实验测试 功率波动 波浪发电 实时采集 对比试验 Distributed temperature sensor, microwave sweeper power fluctuation, temperature accuracy