期刊文献+

一种新型人工颞下颌关节的生物力学分析 被引量:2

Biomechanical analysis of a new type of artificial temporomandibular joint
下载PDF
导出
摘要 目的建立下颌骨髁突缺损有限元模型,研究新型人工颞下颌关节的应力分布及位移改变。方法运用Mimics、Geomagic、Solidworks、ANSYS软件建立含完整牙列的下颌骨右侧髁突缺损有限元模型并分析新型人工颞下颌关节在模拟咬合力加载的情况下假体及下颌骨硬组织的应力分布和位移情况。结果下颌骨整体等效应力值均低于20 MPa,最大形变值不超过0.05 mm。结论新型人工颞下颌关节能避免过大应力导致的假体断裂和骨质吸收,具有良好的生物力学特性。 Objective Mandibular condylar defects in the finite element model is established to study the new artificial temporomandibular joints stress distribution and displacement of the change. Methods Mimics, Geomagic, Solidworks, ANSYS software were used to establish complete denture mandibular condylar defects on the fight side of the finite element model and analyze the new TMJ condylar prosthesis in simulation of the bite force load of mandibular condylar prosthesis and hard tissue stress distribution and displacement. Results The whole Mandibular equivalent stress values were smaller than 20 Mpa, the maximum deformation value was smaller that 0.05 nun. Conclusions New artificial temporomandibular joints can avoid prosthesis fracture and bone absorption caused by excessive stress, and has a good biomechanical properties.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2014年第1期72-75,79,共5页 Chinese Journal of Clinical Anatomy
基金 广东省自然科学基金(S2011010003872) 广州市科技计划项目(7421165457455)
关键词 新型 人工颞下颌关节 生物力学 New type Artificial temporomandibularjoint Biomechanics
  • 相关文献

参考文献18

  • 1Westermark A,Koppel D,Leiggener C.Condylar replacement alone is not sufficient for prosthetic reconstruction of the temporomandibular joint[J].Int J Oral Maxillofac Surg,2006,35(6):488-492.
  • 2Mishima K,Yamada T,Sugahara T.Evaluation of respiratory status and mandibular movement after total temporomandibular joint replacement in patients with rheumatoid arthritis[J].Int J Oral Maxillofac Surg,2003,32(3):275-279.
  • 3Driemel O,Braun S,Muller-Richter UD,et al.Historical development of alloplastic temporomandibular joint replacement after 1945 and state of the art[J].Int J Oral Maxillofac Surg,2009,38(9):909-920.
  • 4Tanaka E,Tanaka M,Watanabe M,et al.Influences of occlusal and skeletal discrepancies on biomechanical environment in the TMJ during maximum clenching: an analytic approach with the finite element method[J].J Oral Rehabil,2001,28(9):888-894.
  • 5Perez D P A,Doblare M.Finite element analysis of the temporomandi bular joint during lateral excursions of the mandible[J].J Biomech,2006,39(12):2153-2163.
  • 6殷学民,李燕,张美超,任晓旭.含完整牙列下颌骨生物力学模型的建立[J].中国口腔颌面外科杂志,2011,9(3):195-197. 被引量:5
  • 7Potter E.Treatment of mandibular angle fractures with a mellea-able noncompression miniplate[J].J Oral Maxillofac Surg,1999,57(4):288-301.
  • 8宫大连,李宁毅,刘云涛,赵保东.成人下颌升支应用解剖的研究[J].中华口腔医学杂志,2004,39(6):513-515. 被引量:9
  • 9Tada S,Stegaroiu R,Kitamura E,et al.Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis[J].Int J Oral Maxillofac Implants,2003,18(3):357-368.
  • 10Hsu JT,Chang CH,Huang HL,et al.The number of screws,bone quality,and friction coefficient affect acetabular cup stability[J].Med Eng Phys,2007,29(10):1089-1095.

二级参考文献17

  • 1史俊,邱蔚六,姜闻博,孙康.兔下颌骨骨折三维有限元模型的建立[J].中国口腔颌面外科杂志,2007,5(3):220-224. 被引量:6
  • 2Field C, Li Q, Li W, et al. Influence of tooth removal on mandibular bone response to mastication[J].Oral Biol,2008,53(12): 1129-1137.
  • 3Shimizu Y. Usui K, Araki K, et al. Study of Finite-element modeling from CT images[J].Dent Mater,2005,24(3):447-455.
  • 4Fernandez JR, Gallas M, Burguera M, et al. A three-dimensional numerical simulation of mandible fracture reduction with screwed miniplates[J].J Biomechan. 2003,36(3):329-337.
  • 5Vollmer D, Meyer U, Joos D. Experimental and finite element study of a human mandible[J].J Craniomaxillofac Surg,2000,28(2):91-96.
  • 6Tie Y. Wang DM, Ji T. Three-dimensional finite-element analysis investigating the biomechanical effects of human mandibular reconstruction with autogenous bone grafts [J].J Craniomaxillofac Surg, 2006,34(5):290-298.
  • 7Erkmen E, Simsek B, Yucel E, et al. Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis Part 1: advancement surgery-posterior loading [J]. Int J Oral Maxillofae Surg,2005,34 (5): 551-558.
  • 8Kawmagh EP, Frawley C. Kearns G. et al. Use of finite element analysis in presurgical planning: treatment of mandibular fractures[J]. Ir J Med Sci,2008,177(4):325-331.
  • 9Mercedes GT, Jose RF. Three-dimensional computer model of the human mandible in two simulated standard trauma situations[J].J Craniomaxillofac Surg 2004.32(5): 303-307.
  • 10Choi AH, Ben-Nissan B, Conwav HC. Three-dimensional modelling and finite element analysis of the human mandible during clenching[J].Aust Dent,2005,50(1):42-48.

共引文献19

同被引文献13

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部