摘要 按照测量不确定度评定的基本方法和程序对卫生纸抗张强度测量结果的不确定度进行了评定,不确定度来源主要是抗张力F-的重复性测量,其次为电子万能试验机校准和试样宽度;卫生纸抗张强度测量结果的扩展不确定度是1.6N/m,包含因子为2;在卫生纸抗张强度测量过程中,应均匀取样,并提高操作者的熟练程度。 The measuring uncertainty of bathroom tissue tensile strength was evaluated according to the basis method and procedure of measuring uncertainty evaluation. Source of uncertainty mainly came from repeated test of tensile strength , then acuracy of electronic universal machine and width of test piece. Expanded uncertainty of bathroom tissue tensile strength was 1.6N/m when the coverage factor was 2. The test piece of tensile strength should be sampled evenly in the process of bathroom tissue ten- sile strength testing, and the operator should improve his skill.
作者 范建云
出处 《黑龙江造纸》 2013年第4期47-48,50,共3页 Heilongjiang Pulp & Paper
关键词 卫生纸 抗张强度 测量 不确定度评定 bathroom tissue tensile strength measure uncertainty
  • 相关文献

参考文献5

  • 1国家质量技术监督局计量司.测量不确定度评定与表示指南[M]{H}北京:中国计量出版社,200519-61.
  • 2国家质量技术监督局.测量不确定度评定与表示[S]{H}北京:中国计量出版社,1999.
  • 3中华人民共和国国家质量监督检验检疫总局.纸、纸板和纸浆试样处理和试验的标准大气条件[S]{H}北京:中国标准出版社,2002.
  • 4中华人民共和国国家质量监督检验检疫总局.纸和纸板试样的采取及试样纵横向、正反面的测定[S]{H}北京:中国标准出版社,2009.
  • 5中华人民共和国国家质量监督检验检疫总局.纸和纸板抗张强度的测定[S]{H}北京:中国标准出版社,2009.