摘要
本文提出了一种低温型冷却塔的设计方案,并对低温型冷却塔的三个主要热力发生过程,即空气与喷淋水的热质交换,溴化锂浓溶液与进塔空气的热质交换,过热水蒸气与溴化锂稀溶液的热量交换,进行热力计算的理论分析。详细介绍了低温型冷却塔的一个应用实例,并对上述叙述的三个热力发生过程,进行了详细的热力计算。
In this paper, we put forward a new low temperature type cooling tower. And we do some theoretical an alyses of thermodynamic calculation, which include the heat and mass transfer of the air and the spray water, the heat and mass transfer of the air and the lithium bromide solution and the heat transfer of the superheated steam and the lithium bromide solution. This paper introduces an example of the low temperature cooling tower to us, and do a detailed research for it.
出处
《制冷》
2013年第4期71-75,共5页
Refrigeration
关键词
低温型冷却塔
溶液除湿
蒸发冷却
Low temperature cooling tower
Lliquid dehumidification
Evaporative cooling