摘要
介绍了在TD-SCDMA无线接入网中Node B的结构和基带单元BBUU的功能。在日常的TD站点基带单元维护工作中出现的故障有很多种,如BBU IR光模块收发异常,IR接口异常告警,光接口性能恶化告警,光模块混插告警,单板心跳检测失败告警,单板硬件故障告警,单板温度异常告警,单板时钟输入异常告警和BBU单板维护链路异常告警等。文章对这些常见故障告警产生的原因进行分析,并提出了故障告警的解决方法。
This paper introduces the Node B in the TD-SCDMA radio access network architecture and the function of baseband unit. There are many failure occurring in the daily maintenance of the TD-SCDMA baseband unit, such as BBU IR optical transceiver module abnormalities, IR interface abnormal alarm, optical interface deterioration alarm, optical module mixed interpolation alarm, single board hearbeat failure alarm, single board hardware failure alarm, single board temperature abnormal alarm, clock input alarm and BBU maintain links abnormal alarm. This article analyzes the causes of these common fault alarms and proposes the solutions.
出处
《电脑与电信》
2013年第12期35-36,共2页
Computer & Telecommunication
基金
武汉职业技术学院院级项目:面向3G岗位群的通信专业能力单元课程的开发
项目编号:2013YJ787